Clinical implications of the body surface area method versus partition model dosimetry for yttrium-90 radioembolization using resin microspheres: a technical review
Authors:
- 4 June 2011
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 25 (7) , 455-461
Abstract
Yttrium-90 (Y-90) radioembolization is becoming established as an effective therapeutic modality for inoperable liver tumors. For resin microspheres, the ‘body surface area (BSA)’ method and the partition model can both be used for Y-90 activity calculation. The BSA method is semi-empirical, but more commonly used due its simplicity. The partition model is more accurate, scientifically sound and personalized, but less popular due to its complexity. This article provides a technical comparison of both methods with an emphasis on its clinical implications. Future dosimetric techniques for Y-90 radioembolization based on emerging technologies are also discussed.Keywords
This publication has 35 references indexed in Scilit:
- Super Selective Radio Embolization of the Porcine Kidney With 90 Yttrium Resin Microspheres: A Feasibility, Safety and Dose Ranging StudyJournal of Urology, 2011
- Computer Modeling of Controlled Microsphere Release and Targeting in a Representative Hepatic Artery SystemAnnals of Biomedical Engineering, 2010
- Multimodality imaging can predict the metabolic response of unresectable colorectal liver metastases to radioembolization therapy with Yttrium-90 labeled resin microspheresPhysics in Medicine & Biology, 2008
- Radioembolisation with 90Y-microspheres: dosimetric and radiobiological investigation for multi-cycle treatmentEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Yttrium-86-labelled human serum albumin microspheres: relation of surface structure with in vivo stabilityNuclear Medicine and Biology, 2008
- Positron-emitting resin microspheres as surrogates of 90Y SIR-Spheres: a radiolabeling and stability studyNuclear Medicine and Biology, 2007
- Developing a New Framework for Dose CalculationJournal of Clinical Oncology, 2006
- Partition model for estimating radiation doses from yttrium-90 microspheres in treating hepatic tumoursEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- Selective internal radiation therapy: Distribution of radiation in the liverEuropean Journal of Cancer and Clinical Oncology, 1989