Expected Flow Parameters Within Hemodialysis Access and Selection for Remedial Intervention of Nonmaturing Conduits
Authors:
- 1 April 2008
- journal article
- research article
- Published by SAGE Publications in Vascular and Endovascular Surgery
- Vol. 42 (2) , 150-158
Abstract
Background Persistent poor patency rates of arteriovenous fistulae and bridge grafts for dialysis access prompted us to investigate whether flow parameters derived from an initial postconstruction, precannulation duplex study could predict access longevity or direct remedial procedures to salvage nonmaturing conduits. Methods We analyzed 125 consecutive dialysis access conduits (34 forearm fistulae, 53 arm fistulae, 38 prosthetic bridge grafts, 108 patients, 82 male/26 female, average age 58 years) over the past 5 years having early (2 to 8 weeks) duplex scanning done prior to attempted hemodialysis cannulation. Velocity waveforms were recorded in the arterial inflow, arterial and venous anastomoses, mid-conduit, and in the venous outflow with averaging of volume flow rate (product of average velocity and cross-sectional area) measured at 3 mid-conduit sites. Conduits were deemed “adequate” for dialysis cannulation or “nonmaturing” by the presence of detected high-grade stenoses (peak systolic velocity >400cm/s, velocity ratio >3, and minimal diameter P = .01). A threshold conduit flow rate of 800 mL/min better discriminated failing and functional fistulae and bridge grafts (accuracy 77%) than a flow rate greater or less than 500 mL/min (accuracy 67%). Remedial interventions doubled average flow rates of “nonmaturing” accesses (from 605 to 1159 mL/min) to values similar to “mature, functional” conduits (1374 mL/min) and facilitated a mean duration of patency (12.9 months) equivalent to conduits not needing remedial interventions (11.5 months). Conclusions Duplex-derived hemodynamic parameters characterized early dialysis access conduit function, prognosticated access patency, guided necessary remedial interventions, and facilitated favorable access longevity.Keywords
This publication has 21 references indexed in Scilit:
- Frequency of critical stenosis in primary arteriovenous fistulae before hemodialysis access: Should duplex ultrasound surveillance be the standard of care?Journal of Vascular Surgery, 2005
- Prospective evaluation of failure modes in autogenous radiocephalic wrist access for haemodialysisNephrology Dialysis Transplantation, 2003
- Impact of reintervention for failing upper-extremity arteriovenous autogenous access for hemodialysisJournal of Vascular Surgery, 2001
- Impact of secondary procedures in autogenous arteriovenous fistula maturation and maintenanceJournal of Vascular Surgery, 2001
- A strategy for increasing use of autogenous hemodialysis access procedures: Impact of preoperative noninvasive evaluationJournal of Vascular Surgery, 1998
- DETECTING VASCULAR ACCESS DYSFUNCTIONASAIO Journal, 1997
- Hemodialysis Access Flow MeasurementASAIO Journal, 1996
- The Effect of Doppler Flow Screening Studies and Elective Revisions on Dialysis Access FailureASAIO Journal, 1992
- Prevention of hemodialysis fistula thrombosis. Early detection of venous stenosesKidney International, 1989
- Duplex ultrasound scanning in the assessment of arteriovenous fistulas created for hemodialysis access: Comparison with digital subtraction angiographyJournal of Vascular Surgery, 1989