An approach for coherent periodogram averaging of tilt‐series data for improved contrast transfer function estimation
Open Access
- 8 May 2025
- journal article
- Published by Wiley in FEBS Open Bio
- Vol. 15 (8) , 1209-1218
Abstract
Cryo‐electron microscopy (cryo‐EM) has become an indispensable technique for determining three‐dimensional structures of biological macromolecules. A critical aspect of achieving high‐resolution cryo‐EM reconstructions is accurately determining and correcting for the microscope's contrast transfer function (CTF). The CTF introduces defocus‐dependent distortions during imaging; if not properly accounted for, the CTF can distort features in and limit the resolution of 3D reconstructions. For tilt‐series data used in cryo‐electron tomography (cryo‐ET), CTF estimation becomes even more challenging due to the tilt of the specimen, which introduces a defocus gradient across the field of view, as well as the low dose and signal in individual tilt images. Here, we describe a simple algorithm to improve the accuracy of CTF estimation of tilted images by leveraging the tilt‐series alignment parameters determined for tomographic reconstruction to explicitly account for the tilted specimen geometry. In brief, each tilt image is divided into patches, each of which are then stretched according to their defocus shift. These are then summed to provide a coherent power spectrum at the tilt axis, which can then be used in standard CTF estimation algorithms. This uses all the data in each image to enhance the visibility of Thon rings, thereby improving high‐resolution CTF estimation and subsequent enhancements in the resolution of subtomogram averages.Keywords
Funding Information
- National Institute of General Medical Sciences (DP2GM146321)
- Pew Charitable Trusts
This publication has 26 references indexed in Scilit:
- Subtomogram Averaging2024
- goCTF: Geometrically optimized CTF determination for single-particle cryo-EMJournal of Structural Biology, 2019
- Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4 ÅJournal of Structural Biology, 2017
- Automated tilt series alignment and tomographic reconstruction in IMODJournal of Structural Biology, 2017
- Implementation of a cryo-electron tomography tilt-scheme optimized for high resolution subtomogram averagingJournal of Structural Biology, 2017
- Gctf: Real-time CTF determination and correctionJournal of Structural Biology, 2016
- CTFFIND4: Fast and accurate defocus estimation from electron micrographsJournal of Structural Biology, 2015
- Contrast transfer function correction applied to cryo-electron tomography and sub-tomogram averagingJournal of Structural Biology, 2009
- Fiducial Marker and Hybrid Alignment Methods for Single- and Double-axis Tomography2008
- Automated electron microscope tomography using robust prediction of specimen movementsJournal of Structural Biology, 2005