Glycan‐Selective MALDI In‐Source Decay Analysis of Intact Glycoproteins
Open Access
- 14 December 2021
- journal article
- research article
- Published by Wiley in Analysis & Sensing
- Vol. 2 (2)
Abstract
A simple matrix‐assisted laser desorption/ionization‐time‐of‐flight (MALDI‐TOF) mass spectrometry (MS) approach has been developed to analyze the structural pattern of glycan on glycoproteins without any digestive or modification pretreatment. For a 7 pmol sample of intact glycoprotein, RNase B, a solid ionic matrix DHB‐aniline‐sodium enabled a regioselective in‐source decay (ISD) and glycan‐selective ionization as a sodium adduct ion, [M+Na]+. This matrix significantly reduced the formation of peptide‐fragment‐derived ions, and a high‐mannose‐type glycan pattern was observed. This ISD product ion was formed by selective cleavage of the reducing end of the glycan by 0,2A or 2,4A type cross‐ring cleavage. Pseudo‐MS3‐type post‐source decay (PSD) analysis of an A type ion indicated the regioselectivity of the ISD fragmentation and the glycan sequence. Combining ISD glycomics with conventional ISD proteomics will accelerate quality control for glycoprotein drugs and biomarker discovery.Keywords
Funding Information
- JKA Foundation (2019M-165)
- Hokkaido University
This publication has 20 references indexed in Scilit:
- A Comparison of Energy-Resolved Vibrational Activation/Dissociation Characteristics of Protonated and Sodiated High Mannose N-GlycopeptidesJournal of the American Society for Mass Spectrometry, 2015
- Cotton HILIC SPE Microtips for Microscale Purification and Enrichment of Glycans and GlycopeptidesAnalytical Chemistry, 2011
- Ionic Liquid Matrixes Optimized for MALDI-MS of Sulfated/Sialylated/Neutral Oligosaccharides and GlycopeptidesAnalytical Chemistry, 2008
- Rational Selection of the Optimum MALDI Matrix for Top-Down Proteomics by In-Source DecayAnalytical Chemistry, 2007
- Rapid and Simple Solid‐Phase Esterification of Sialic Acid Residues for Quantitative Glycomics by Mass SpectrometryChemistry – A European Journal, 2007
- Use of a 2,5-Dihydroxybenzoic Acid/Aniline MALDI Matrix for Improved Detection and On-Target Derivatization of Glycans: A Preliminary ReportAnalytical Chemistry, 2006
- High‐Throughput Protein Glycomics: Combined Use of Chemoselective Glycoblotting and MALDI‐TOF/TOF Mass SpectrometryAngewandte Chemie International Edition, 2004
- High‐Throughput Protein Glycomics: Combined Use of Chemoselective Glycoblotting and MALDI‐TOF/TOF Mass SpectrometryAngewandte Chemie, 2004
- Structural Characterization of N-Glycopeptides by Matrix-Dependent Selective Fragmentation of MALDI-TOF/TOF Tandem Mass SpectrometryAnalytical Chemistry, 2004
- T3-Sequencing: Targeted Characterization of the N- and C-Termini of Undigested Proteins by Mass SpectrometryAnalytical Chemistry, 2003