Toward Standardization of BK Virus Monitoring: Evaluation of the BK Virus R-gene Kit for Quantification of BK Viral Load in Urine, Whole-Blood, and Plasma Specimens
Open Access
- 1 December 2014
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 52 (12) , 4298-4304
Abstract
Screening of BK virus (BKV) replication is recommended to identify patients at increased risk of BKV-associated diseases. However, the heterogeneity of molecular techniques hinders the establishment of universal guidelines for BKV monitoring. Here we aimed to compare the performance of the CE-marked BK virus R-gene kit (R-gene) to the performance of our in-house assay for quantification of BKV DNA loads (BKVL). A 12-specimen panel from the Quality Control for Molecular Diagnostics (QCMD) organization, 163 urine samples, and 88 paired specimens of plasma and whole blood (WB) from transplant recipients were tested. Both the R-gene and in-house assays showed a good correlation within the QCMD panel (r = 0.995 and r = 0.989, respectively). BKVL were highly correlated between assays, although positive biases were observed with the in-house assay in analysis of urine (0.72 ± 0.83 log10 copies/ml), plasma (1.17 ± 0.63 log10 copies/ml), and WB (1.28 ± 0.37 log10 copies/ml). Recalibration with a common calibrator significantly reduced the bias in comparisons between assays. In contrast, BKVL was underestimated with the in-house PCR in eight samples containing BKV genotype II, presenting point mutations at primer-annealing sites. Using the R-gene assay, plasma and WB specimens were found to be equally suitable for quantification of BKVL, as indicated by the high correlation coefficient (r = 0.965, P < 0.0001). In conclusion, the R-gene assay demonstrated reliable performance and higher accuracy than the in-house assay for quantification of BKVL in urine and blood specimens. Screening of BKV replication by a well-validated commercial kit may enable clinical laboratories to assess viral loads with greater reproducibility and precision.Keywords
This publication has 32 references indexed in Scilit:
- Donor origin of BKV replication after kidney transplantationJournal of Clinical Virology, 2014
- Currently recommended BK virus (BKV) plasma viral load cutoff of ≥4 log10/mL underestimates the diagnosis of BKV‐associated nephropathy: a single transplant center experienceTransplant Infectious Disease, 2013
- BK Virus: Opportunity Makes a PathogenClinical Infectious Diseases, 2005
- A Prospective Longitudinal Study of BK Virus Infection in 104 Renal Transplant RecipientsAmerican Journal of Transplantation, 2005
- Polyomavirus-Associated Nephropathy in Renal Transplantation: Interdisciplinary Analyses and RecommendationsTransplantation, 2005
- Assessment of automated DNA extraction coupled with real-time PCR for measuring Epstein–Barr virus load in whole blood, peripheral mononuclear cells and plasmaJournal of Clinical Virology, 2004
- Prospective Study of Polyomavirus Type BK Replication and Nephropathy in Renal-Transplant RecipientsNew England Journal of Medicine, 2002
- External Quality Assessment Program for Qualitative and Quantitative Detection of Hepatitis C Virus RNA in Diagnostic VirologyJournal of Clinical Microbiology, 2002
- DNA sequencing of viral capsid protein VP-1 region in patients with BK virus interstitial nephritisTransplantation, 2002
- Toward Standardization of Epstein-Barr Virus DNA Load Monitoring: Unfractionated Whole Blood as Preferred Clinical SpecimenJournal of Clinical Microbiology, 2001