In vitrocharacteristics of a gelling PEGDA-QT polymer system with model drug release for cerebral aneurysm embolization
- 7 June 2013
- journal article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Abstract
A liquid‐to‐solid gelling polymer system, such as the poly(ethylene glycol) diacrylate‐pentaerythritol tetrakis (3‐mercaptopropionate) (PEGDA‐QT) system, can fill cerebral aneurysms more completely than current embolization materials, reducing the likelihood of aneurysm recurrence. PEGDA‐QT gels were formulated using PEGDA of different molecular weights (PEGDA575 and PEGDA700), and their characteristics were examined in vitro. Experiments examined gel time, mass change, crosslink integrity, cytotoxicity, and protein release capabilities. In general, PEGDA575‐QT gels were more hydrophobic, requiring an initiating solution with a higher pH (pH 9.5) to achieve a gel time comparable to PEGDA700‐QT gels, which used an initiating solution at pH 9.19. The mass change and crosslink integrity of gels were analyzed over time after gels were submerged in 150 mM phosphate buffered saline. After 380 days, PEGDA575‐QT gels achieved a maximum mass increase of 72% due to water uptake, while PEGDA700‐QT gels doubled their initial mass (100% increase) by 165 days. Compression tests showed that PEGDA700‐QT gels hydrolyzed more quickly than PEGDA575‐QT gels. Cytotoxicity assays showed that in general, PEGDA575‐QT negatively affected cell growth, while PEGDA700‐QT gels promoted cell viability. Sustained, controlled release of lysozyme, a 14.3 kDa protein, was achieved over an 8‐week period when loaded into PEGDA700‐QT gels, but PEGDA575‐QT gels did not show sustained release. These studies show that although they are similar in composition, these PEGDA‐QT gel formulations behave considerably differently. Although PEGDA700‐QT gels swell more and degrade faster than PEGDA575‐QT gels, their cytocompatibility and protein release characteristics may prove to be more beneficial for in vivo aneurysm treatment. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2013.Keywords
This publication has 22 references indexed in Scilit:
- Accelerated in vitro release testing of implantable PLGA microsphere/PVA hydrogel composite coatingsInternational Journal of Pharmaceutics, 2012
- Gelling process differences in reverse emulsion, in situ gelling polymeric materials for intracranial aneurysm embolization, formulated with injectable contrast agentsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2010
- Analysis of degradation data of poly(l-lactide–co-l,d-lactide) and poly(l-lactide) obtained at elevated and physiological temperatures using mathematical modelsActa Biomaterialia, 2010
- In vitro hydrolytic degradation of centrifugally spun polyhydroxybutyrate–pectin composite fibresPolymer International, 2009
- Coiling of Very Large and Giant Basilar Tip Aneurysms: Midterm Clinical and Angiographic ResultsAmerican Journal of Neuroradiology, 2007
- Controlling delivery properties of a waterborne, in‐situ‐forming biomaterialJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2006
- Guglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experienceJournal of Neurosurgery, 2003
- International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: a randomised trialThe Lancet, 2002
- Case-Fatality Rates and Functional Outcome After Subarachnoid HemorrhageStroke, 1997
- A simple equation for description of solute release II. Fickian and anomalous release from swellable devicesJournal of Controlled Release, 1987