Aerosol protection using modified N95 respirator during upper gastrointestinal endoscopy: a randomized controlled trial
Authors:
- Chawisa NampoolsuksanCNChawisa Nampoolsuksan
- Thawatchai AkaraviputhTAThawatchai Akaraviputh
- Asada MethasateAMAsada Methasate
- Jirawat SwangsriJSJirawat Swangsri
- Atthaphorn TrakarnsangaATAtthaphorn Trakarnsanga
- Chainarong PhalanusitthephaCPChainarong Phalanusitthepha
- Thammawat ParakonthunTPThammawat Parakonthun
- Voraboot TaweerutchanaVTVoraboot Taweerutchana
- Nicha SrisuworananNSNicha Srisuworanan
- Tharathorn SuwatthanarakTSTharathorn Suwatthanarak
- Thikhamporn TawantanakornTTThikhamporn Tawantanakorn
- Varut LohsiriwatVLVarut Lohsiriwat
Open Access
- 30 May 2024
- journal article
- research article
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 57 (3) , 335-341
Abstract
Background/Aims: The coronavirus disease 2019 pandemic has affected the worldwide practice of upper gastrointestinal endoscopy. Here we designed a modified N95 respirator with a channel for endoscope insertion and evaluated its efficacy in upper gastrointestinal endoscopy.Methods: Thirty patients scheduled for upper gastrointestinal endoscopy were randomized into the modified N95 (n=15) or control (n=15) group. The mask was placed on the patient after anesthesia administration and particles were counted every minute before (baseline) and during the procedure by a TSI AeroTrak particle counter (9306-04; TSI Inc.) and categorized by size (0.3, 0.5, 1, 3, 5, and 10 µm). Differences in particle counts between time points were recorded.Results: During the procedure, the modified N95 group displayed significantly smaller overall particle sizes than the control group (median [interquartile range], 231 [54–385] vs. 579 [213–1,379]×103/m3; p=0.056). However, the intervention group had a significant decrease in 0.3-µm particles (68 [–25–185] vs. 242 [72–588]×103/m3; p=0.045). No adverse events occurred in either group. The device did not cause any inconvenience to the endoscopists or patients.Conclusions: This modified N95 respirator reduced the number of particles, especially 0.3-µm particles, generated during upper gastrointestinal endoscopy.Keywords
This publication has 20 references indexed in Scilit:
- New protection barrier for endoscopic procedures in the era of pandemic COVID-19VideoGIE, 2020
- A Proof of Concept Study: Esophagogastroduodenoscopy Is an Aerosol-Generating Procedure and Continuous Oral Suction During the Procedure Reduces the Amount of Aerosol GeneratedGastroenterology, 2020
- Aerosols Produced by Upper Gastrointestinal Endoscopy: A Quantitative EvaluationAmerican Journal of Gastroenterology, 2020
- Endoscopic shield: barrier enclosure during the endoscopy to prevent aerosol droplets during the COVID-19 pandemicVideoGIE, 2020
- “Double-surgical-mask-with-slit” method: reducing exposure to aerosol generation at upper gastrointestinal endoscopy during the COVID-19 pandemicEndoscopy, 2020
- SARS‐CoV‐2 can be detected in urine, blood, anal swabs, and oropharyngeal swabs specimensJournal of Medical Virology, 2020
- ESGE and ESGENA Position Statement on gastrointestinal endoscopy and the COVID-19 pandemicEndoscopy, 2020
- SARS-CoV-2 (COVID-19) by the numberseLife, 2020
- SARS-CoV2 in different body fluids, risks of transmission, and preventing COVID-19: A comprehensive evidence-based reviewInternational Journal of Preventive Medicine, 2020
- Aerosol Generating Procedures and Risk of Transmission of Acute Respiratory Infections to Healthcare Workers: A Systematic ReviewPLOS ONE, 2012