Summary: The tritium compatible Roots pump Okta 1500 (Pfeiffer Vacuum) is designed for pumping light gas species consisting of diluted radioactive gas, especially tritium mixed with other hydrogen isotopes and helium. Therefore, the pump is constructed of stainless steel and equipped with a special gas lubricated mechanical seal.The series of experiments presented in this work include the evaluation of the performance and an integrity check of the glide ring seal as well as the determination of the light gas pumping performance at low pressure. Those qualifications are needed for efficient embedding of the pump in the International Thermonuclear Experimental Fusion Reactor (ITER) project. As a nuclear facility (Installation Nucléaire de Base, INB) ITER is operated in accordance with the French nuclear safety regulations (INB guidelines) that demand qualification and integrity of the tritium bearing equipment to maintain performance and confinement of active gases at every stages via design, testing, commissioning, operation and surveillance. The experimental methodologies and findings are important to advocate the qualification of the pump for the purpose of radioactive light gas pumping as a roughing pump to back Torus high vacuum cryogenic pump.