Isomorphic contact resonance force microscopy and piezoresponse force microscopy of an AlN thin film: demonstration of a new contact resonance technique
- 1 June 2020
- journal article
- research article
- Published by IOP Publishing in Nano Futures
- Vol. 4 (2) , 025003
Abstract
We present a new contact resonance force microscopy (CRFM) imaging technique, isomorphic contact resonance (iso-CR), that acquires data at a constant contact resonance (CR) frequency, and hence constant tip-sample contact stiffness across the scan area. Constant CR frequency is obtained by performing force versus distance measurements to vary the applied force at each pixel (i.e. force-volume mapping mode). The CR frequency increases with increasing applied force; thus, a carefully selected target frequency will be reached for most pixels at some point in the force versus distance curve. In the iso-CR mode, the cantilever maintains an invariant vibrational shape and a constant environmental damping, thus simplifying interpretation of amplitude and quality factor contrast compared to conventional CRFM. Iso-CR imaging of a piezoelectric AlN thin film sample is demonstrated. Iso-CRFM images were obtained by mechanically driving the base of the cantilever, and iso-CR piezoresponse force microscopy (iso-CR-PFM) images were obtained by electrically biasing the tip. The PFM phase images reveal that the sample contains nanoscale Al-polar (or ‘up’) and N-polar (or ‘down’) domains, with ≈180° phase contrast between oppositely polarized domains. The PFM amplitude and Q-factor images also show ‘up’ vs. ‘down’ domain contrast, which decreases with increasing CR frequency. The frequency-dependent amplitude and Q contrast is ascribed to a frequency-dependent electrostatic contribution to the signal. Domain contrast is not observed in the CRFM (mechanically driven) images. To summarize, the iso-CR capability to control the resonance frequency across multiple excitation schemes helps elucidate the origin of the electromechanical and nanomechanical image contrast.Keywords
This publication has 28 references indexed in Scilit:
- Microcantilever Q control via capacitive couplingApplied Physics Letters, 2012
- Spring constant calibration of atomic force microscope cantilevers of arbitrary shapeReview of Scientific Instruments, 2012
- Mapping nanoscale elasticity and dissipation using dual frequency contact resonance AFMNanotechnology, 2011
- Real Space Mapping of Li-Ion Transport in Amorphous Si Anodes with Nanometer ResolutionNano Letters, 2010
- The band excitation method in scanning probe microscopy for rapid mapping of energy dissipation on the nanoscaleNanotechnology, 2007
- Finite optical spot size and position corrections in thermal spring constant calibrationNanotechnology, 2004
- Contact-Resonance Piezoresponse Force Microscope and Its Application to Domain Observation of Pb(Mg1/3Nb2/3)O3–PbTiO3Single CrystalsJapanese Journal of Applied Physics, 2003
- Atomic and electrostatic force microscopy observations on gallium nitridePhysica Status Solidi (a), 2003
- Calibration of rectangular atomic force microscope cantileversReview of Scientific Instruments, 1999
- Calibration of atomic-force microscope tipsReview of Scientific Instruments, 1993