Peptide Separation in Normal Phase Liquid Chromatography
Author:
- 1 August 1997
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (15) , 3038-3043
Abstract
A new method is established for separating peptides in normal phase liquid chromatography using TSK gel Amide-80, carbamoyl groups bonded to a silica gel matrix, and an acetonitrile−water solution containing 0.1% trifluoroacetic acid. Peptide retention time increased with acetonitrile concentration in the initial eluent. Hydrophilic peptides with no retention in a reversed phase column were retained and separated in the present method. Separation selectivities in the present and reversed phase methods differed significantly. Two-dimensional separation of protein digest using reversed and normal phases was conducted, taking advantage of the differences in selectivities. All peptides obtained from the digest could be separated completely. The present method is useful for separating peptide mixtures in conjunction with reversed phase liquid chromatography. Peptide recovery from the Amide-80 column exceeded 80%, as with the reversed phase column, and repeatability and reproducibility were satisfactory.Keywords
This publication has 23 references indexed in Scilit:
- Chromatographic behaviour of phenylurea pesticides in high-performance liquid chromatography with nitrile- and amino-bonded stationary phasesJournal of Chromatography A, 1994
- Why does ribonuclease irreversibly inactivate at high temperatures?Biochemistry, 1986
- Retention of carbohydrates on silica and amine-bonded silica stationary phases: application of the hydration modelJournal of Chromatography A, 1985
- Prediction of retention data of protected dipeptides in normal phase high-performance liquid chromatographyJournal of Chromatography A, 1985
- Study of the high-performance liquid chromatographic separation of reducing sugars, applied to the determination of lactose in milkJournal of Chromatography A, 1983
- Mobile phase effects in liquid-solid chromatographyJournal of Chromatography A, 1983
- Retention mechanism and the role of the mobile phase in normal-phase separation on amino-bonded-phase columnsAnalytical Chemistry, 1982
- Mechanism of solute retention in liquid—solid chromatography and the role of the mobile phase in affecting separationJournal of Chromatography A, 1980
- An expanded solubility parameter treatment for classification and use of chromatographic solvents and adsorbentsJournal of Chromatography A, 1976
- Determination of dimethylnitrosamine and nitrosoproline by differential pulse polarographyAnalytical Chemistry, 1975