Radial shearing interferometer for in-process measurement of diamond turning
Authors:
- 1 October 2000
- journal article
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 39 (10) , 2696-2699
Abstract
A stable interferometer with two zone plates to measure a concave mirror figure is developed. The principle of the measurement is based on the radial shearing interference in which the measuring wavefront from the entire mirror surface under test is referred to that from the central part. On-machine experiments show that the interferometer is stable and compact enough to be applicable to in-process measurement for diamond turning at about 0.06 ?m p-v accuracy.Keywords
This publication has 5 references indexed in Scilit:
- Shape measurements of mirror surfaces with a lateral-shearing interferometer during machine runningPrecision Engineering, 1998
- Figure Measurement of Concave Mirror by Fiber-Grating Hartmann TestOptical Review, 1994
- In-process measurement and a workpiece-referred form accuracy control system (WORFAC): concept of the method and preliminary experimentPrecision Engineering, 1989
- Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometryJournal of the Optical Society of America, 1982
- Holographic Radial Shear InterferometerApplied Optics, 1974