Blower-door estimates of PM2.5 deposition rates and penetration factors in an idealized room
- 11 August 2020
- journal article
- research article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 31 (8) , 2064-2082
Abstract
Particle deposition and penetration in buildings has been widely studied, but the effect of indoor characteristics merits further investigation, so improved experimental methods may be needed. The present study measured indoor and outdoor concentrations of PM2.5 and estimated PM2.5 deposition rates and penetration factors under a variety of different indoor situations, with a novel method (blower-door method). The blower-door method is compared with the standard decay and rebound method for an idealized room (a portable building test cell; 6.08 m [ ] 2.40 m [ ] 2.60 m) under eight testing scenarios (empty, cardboard boxes in three arrangements, terry cloth wall covering, and three sets of window holes); run three times to establish the coefficient of variation representing precision. Results show that higher induced indoor–outdoor pressure differences cause a larger variation of estimated effective deposition rate on different indoor surfaces. The deposition rate and penetration factor may be influenced by indoor surface materials. The blower-door method gives higher precision for the estimates, and detects subtle differences in penetration factors, which may be difficult using the decay and rebound method.Keywords
This publication has 37 references indexed in Scilit:
- Residential indoor and outdoor ultrafine particles in Windsor, OntarioAtmospheric Environment, 2011
- Ultrafine particle concentrations and exposures in seven residences in northern CaliforniaIndoor Air, 2010
- Particulate Matter Air Pollution and Cardiovascular DiseaseCirculation, 2010
- Indoor ultrafine particles and childhood asthma: exploring a potential public health concernIndoor Air, 2007
- Computational analysis of wind driven natural ventilation in buildingsEnergy and Buildings, 2006
- Particle deposition rates in residential housesAtmospheric Environment, 2005
- Use of Real-Time Light Scattering Data To Estimate the Contribution of Infiltrated and Indoor-Generated Particles to Indoor AirEnvironmental Science & Technology, 2003
- The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutantsJournal of Exposure Science & Environmental Epidemiology, 2001
- Estimates of the energy impact of ventilation and associated financial expendituresEnergy and Buildings, 2001
- An Association between Air Pollution and Mortality in Six U.S. CitiesThe New England journal of medicine, 1993