Use of Ultrasound in Spinal Arthrodesis
Authors:
- 15 May 1998
- journal article
- basic science
- Published by Wolters Kluwer Health in Spine
- Vol. 23 (10) , 1142-1148
Abstract
Study Design. The biomechanical and histologic characteristics of posterolateral spinal fusion in a rabbit model with and without the application of low-intensity ultrasound were analyzed. Objectives. To evaluate the use of ultrasound to improve the spinal fusion rate and biomechanical characteristics of the fusion mass in a rabbit model. Summary of Background Data. This is the first study in which the benefits of ultrasound in spinal fusion have been assessed. Posterolateral intertransverse process fusion in the rabbit has a pseudarthrosis rate similar to that recorded in humans (5-40%). Methods. Fourteen New Zealand White rabbits were randomly assigned to each of two groups to undergo spinal fusion using autologous bone with ultrasound or autologous bone without ultrasound. A specially designed plastic constraint was used to focus the ultrasound over the rabbits' lumbar spine 20 minutes per day. Animals were killed at 6 weeks for biomechanical and histologic testing. Results. The rate of pseudarthrosis, evaluated radiographically and manually in a blinded fashion, decreased at a statistically significant rate (from 35% to 7%) with ultrasound. Biomechanical analysis of the fusion mass showed that ultrasound resulted in statistically significant increases in stiffness (33%; P = 0.03), area under the load displacement curve (25%; P = 0.05), and load to failure of the fusion mass (24%; P = 0.04). Qualitative histologic assessment showed increased bone formation in those fusions exposed to ultrasound. Conclusions. Lumbar spinal fusion is a complex biologic process. The results of the current study demonstrate the reproducibility of a rabbit fusion model and the ability of ultrasound to induce a statistically significant increase in fusion rate, stiffness, area under the load displacement curve, and load to failure of the fusion mass. These results provide a basis for continued evaluation of biologic improvement of spinal arthrodesis with the use of ultrasound.Keywords
This publication has 33 references indexed in Scilit:
- Effect of medium pH on osteoclast activity and osteoclast formation in cultures of dispersed rabbit osteoclastsJournal of Bone and Mineral Research, 1993
- Biological Effects on the Cellular Level of Electric Field PulsesHealth Physics, 1991
- Non-Invasive Low-Intensity Pulsed Ultrasound Accelerates Bone Healing in the RabbitJournal of Orthopaedic Trauma, 1990
- The Effect of Low Power Specifically Programmed Ultrasound on the Healing Time of Fresh Fractures Using a Collesʼ ModelJournal of Orthopaedic Trauma, 1990
- The Effects of Therapeutic Ultrasound on Tendon HealingAmerican Journal of Physical Medicine & Rehabilitation, 1989
- The effect of ultrasound on the healing of repaired cockerel tendon: Is collagen crosslinkage a factor?Journal of Hand Surgery (European Volume), 1989
- Kinetics of channelized membrane ions in magnetic fieldsBioelectromagnetics, 1988
- External ultrasound can generate microampere direct currents in vivo from implanted piezoelectric materialsJournal of Orthopaedic Research, 1988
- Functional, Mechanical, and Biochemical Assessment of Ultrasound Therapy on Tendon Healing in the Chicken ToePlastic and Reconstructive Surgery, 1986
- The Effect of Ultrasonic and Thermal Treatment on WoundsPlastic and Reconstructive Surgery, 1981