Reliability of automated versus handheld breast ultrasound examinations of suspicious breast masses
Open Access
- 1 July 2019
- journal article
- research article
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 38 (3) , 264-271
Abstract
Purpose: The purpose of this study was to assess the reliability of automated breast ultrasound (ABUS) examinations of suspicious breast masses in comparison to handheld breast ultrasound (HHUS) with regard to Breast Imaging Reporting and Data System (BI-RADS) category assessment, and to investigate the factors affecting discrepancies in categorization. Methods: A total of 135 masses that were assessed as BI-RADS categories 4 and 5 on ABUS that underwent ultrasound (US)-guided core needle biopsy from May 2017 to December 2017 were included in this study. The BI-RADS categories were re-assessed using HHUS. Agreement of the BI-RADS categories was evaluated using kappa statistics, and the positive predictive value of each examination was calculated. Logistic regression analysis was performed to identify the mammography and US findings associated with discrepancies in the BI-RADS categorization. Results: The overall agreement between ABUS and HHUS in all cases was good (79.3%, kappa=0.61, P<0.001). Logistic regression analysis revealed that accompanying suspicious microcalcifications on mammography (odds ratio PR], 4.63; 95% confidence interval [CI], 1.83 to 11.71; P=0.001) and an irregular shape on US (OR, 5.59; 95% CI, 1.43 to 21.83; P=0.013) were associated with discrepancies in the BI-RADS categorization. Conclusion: The agreement between ABUS and HHUS examinations in the BI-RADS categorization of suspicious breast masses was good. The presence of suspicious microcalcifications on mammography and an irregular shape on US were factors associated with ABUS yielding a lower level of suspicion than HHUS in terms of the BI-RADS category assessment.Keywords
This publication has 22 references indexed in Scilit:
- Assessing Improvement in Detection of Breast Cancer with Three-dimensional Automated Breast US in Women with Dense Breast Tissue: The SomoInsight StudyRadiology, 2015
- Interobserver agreement on the interpretation of automated whole breast ultrasonographyUltrasonography, 2014
- Differentiation of benign and malignant breast lesions: A comparison between automatically generated breast volume scans and handheld ultrasound examinationsEuropean Journal of Radiology, 2012
- Detection of Breast Cancer With Addition of Annual Screening Ultrasound or a Single Screening MRI to Mammography in Women With Elevated Breast Cancer RiskJAMA, 2012
- Breast cancers initially detected by hand-held ultrasound: detection performance of radiologists using automated breast ultrasound dataActa Radiologica, 2011
- Analysis of 107 breast lesions with automated 3D ultrasound and comparison with mammography and manual ultrasoundEuropean Journal of Radiology, 2009
- Tailored Supplemental Screening for Breast Cancer: What Now and What Next?American Journal of Roentgenology, 2009
- Diagnostic Performance of Digital versus Film Mammography for Breast-Cancer ScreeningNew England Journal of Medicine, 2005
- The case for early detectionNature Reviews Cancer, 2003
- Comparison of the Performance of Screening Mammography, Physical Examination, and Breast US and Evaluation of Factors that Influence Them: An Analysis of 27,825 Patient EvaluationsRadiology, 2002