Ultrasound generation in single-crystal silicon using a pulsed Nd:YAG laser
- 14 May 1996
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 29 (5) , 1345-1348
Abstract
The performance of a Q-switched Nd:YAG laser as an ultrasonic source in a single-crystal silicon sample has been studied using a wide-bandwidth modified Michelson interferometer as an absolute displacement sensor. At low power densities the source is an extended buried thermoelastic source; however, the thermal expansion is less than the contraction due to the negative pressure coefficient of the energy gap and the illuminated region contracts rather than expands. Above a certain power density, ablation occurs, giving rise to a localized normal force at the surface of the sample.Keywords
This publication has 7 references indexed in Scilit:
- Ultrafast generation of acoustic waves in copperIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Time domain dynamic response functions of elastically anisotropic solidsThe Journal of the Acoustical Society of America, 1994
- Laser-generated ultrasound: its properties, mechanisms and multifarious applicationsJournal of Physics D: Applied Physics, 1993
- Picosecond ultrasonicsIEEE Journal of Quantum Electronics, 1989
- On epicentral waveforms for laser-generated ultrasoundJournal of Physics D: Applied Physics, 1986
- Electronic Volume Effect in SiliconPhysical Review Letters, 1967
- Generation of Elastic Waves by Transient Surface HeatingJournal of Applied Physics, 1963