MATRIX SOLID PHASE DISPERSION FOR THE EXTRACTION OF BISPHENOL-A FROM HUMAN BREAST MILK PRIOR TO HPLC ANALYSIS
- 23 October 2013
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 37 (2) , 247-258
Abstract
Matrix Solid Phase Dispersion was applied to the effective and quantitative extraction of Bisphenol A (4,4′-(propane-2,2-diyl)diphenol) from human breast milk. A reversed phase high performance liquid chromatographic method was further developed and validated. The mobile phase consisted of CH3CN-H2O (70:30, v/v) and was delivered isocratically. The analytical column was Hichrom Kromasil 100-5C18 (250 × 4.6 mm, 5 µm) and was operated at ambient temperature. UV detection was performed at 230 nm. Sample preparation was achieved with matrix solid phase dispersion (MSPD) using the sorbent of Lichrolut cartridges with high recoveries (95.5%). The detection limit of the method was 5.3 µg/kg. Triethylene glycol dimethacrylate (TEGDMA) was used as internal standard. Validation of the method was performed in terms of accuracy and precision: within-day assay (n = 6) and between-day assay (n = 3 × 3) and was found to be satisfactory, with high accuracy and precision results. The developed method was comparatively applied to the analysis of commercial cow milk samples with success.Keywords
This publication has 24 references indexed in Scilit:
- Simultaneous determination of bisphenol A, octylphenol, and nonylphenol by pressurised liquid extraction and liquid chromatography–tandem mass spectrometry in powdered milk and infant formulasFood Chemistry, 2011
- Determination of bisphenol A in Iranian packaged milk by solid-phase extraction and HPLCMonatshefte für Chemie - Chemical Monthly, 2010
- Determination of Bisphenol A in U.S. Infant Formulas: Updated Methods and ConcentrationsJournal of Agricultural and Food Chemistry, 2010
- Breast Cancer Epidemiology2010
- Levels of Bisphenol A in Canned Liquid Infant Formula Products in Canada and Dietary Intake EstimatesJournal of Agricultural and Food Chemistry, 2008
- Automated on-line column-switching HPLC-MS/MS method with peak focusing for measuring parabens, triclosan, and other environmental phenols in human milkAnalytica Chimica Acta, 2008
- Bisphenol A diglycidyl ether (BADGE) migrating from packaging material ‘disappears’ in food: reaction with food componentsFood Additives & Contaminants: Part A, 2008
- Human exposure to bisphenol A (BPA)Reproductive Toxicology, 2007
- Determination of bisphenol A in human breast milk by HPLC with column‐switching and fluorescence detectionBiomedical Chromatography, 2004
- Determination of bisphenol A in, and its migration from, PVC stretch film used for food packagingFood Additives & Contaminants, 2003