The Theoretical Analysis of Open-Loop Characteristic for Double Magnetic Detector Comparator
Authors:
- 21 March 2005
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 54 (2) , 592-594
Abstract
An original double detector sensing theory with magnetic modulator and magnetic amplifier is discussed. The open-loop characteristic of the double detector is calculated theoretically and the double magnetic detector comparator has been constructed for testing and performance evaluation. Both the calculation and testing prove that the open-loop characteristic of the double detector comparator has only one operating point corresponding to zero ampere turns, and no other zero output points or so called false-balance points. The double detector comparator possesses not only high sensitivity, low drift, high linearity and good antimagnetic property for magnetic modulator comparators, but also good stability and reliability for magnetic amplifiers.Keywords
This publication has 5 references indexed in Scilit:
- A double detector dc comparator with magnetic modulator and magnetic amplifier2002
- A 300 000- a high precision DC comparator for on-line calibration and measurementIEEE Transactions on Instrumentation and Measurement, 1991
- A 100000-A high precision on-site measurement calibration device for heavy direct currentIEEE Transactions on Instrumentation and Measurement, 1990
- The Current Comparator1988
- A self-balancing direct current comparator for 20 000 amperesIEEE Transactions on Magnetics, 1965