Modeling Vibrations of a Tiled Talbot-Lau Interferometer on a Clinical CT
Open Access
- 27 October 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (3) , 774-784
Abstract
X-ray computed tomography (CT) is an invaluable imaging technique for non-invasive medical diagnosis. However, for soft tissue in the human body the difference in attenuation is inherently small. Grating-based X-ray phase-contrast is a relatively novel imaging method which detects additional interaction mechanisms between photons and matter, namely refraction and small-angle scattering, to generate additional images with different contrast. The experimental setup involves a Talbot-Lau interferometer whose susceptibility to mechanical vibrations hindered acquisition schemes suitable for clinical routine in the past. We present a processing pipeline to identify spatially and temporally variable fluctuations occurring in an interferometer installed on a continuously rotating clinical CT gantry. The correlations of the vibrations in the modular grating setup are exploited to identify a small number of relevant fluctuation modes, allowing for a sample reconstruction free of vibration artifacts.Keywords
All Related Versions
Funding Information
- Karlsruhe Nano Micro Facility, Helmholtz Research Infrastructure at Karlsruhe Institute of Technology
- Technical University of Munich (TUM) Institute for Advanced Study
- European Research Council (AdG 695045)
- Philips DACH GmbH.
This publication has 33 references indexed in Scilit:
- Pulmonary Emphysema Diagnosis with a Preclinical Small-Animal X-ray Dark-Field Scatter-Contrast ScannerRadiology, 2013
- Cadaveric and in vivo human joint imaging based on differential phase contrast by X-ray Talbot-Lau interferometryZeitschrift für Medizinische Physik, 2013
- Experimental results from a preclinical X-ray phase-contrast CT scannerProceedings of the National Academy of Sciences, 2012
- Trimodal low-dose X-ray tomographyProceedings of the National Academy of Sciences, 2012
- Hard-X-ray dark-field imaging using a grating interferometerNature Materials, 2008
- Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sourcesNature Physics, 2006
- Demonstration of X-Ray Talbot InterferometryJapanese Journal of Applied Physics, 2003
- Simultaneous calculation of phase distribution and scanning phase shift in phase shifting interferometryOptics Communications, 1991
- On the limited memory BFGS method for large scale optimizationMathematical Programming, 1989
- An interferometer based on the Talbot effectOptics Communications, 1971