Abstract
It has been known for some time that electrochemical measurements are nonpredictive in inhibited concentrated hydrochloric acid at high temperatures. Extensive investigations into the weight loss to linear polarization (LP) rate ratio (R) have revealed the latter to be both very sensitive to the chemical nature of the inhibitor as well as time dependent. R can vary from 1 to 7 for different inhibitors and/or over a 24-h time period for the same inhibitor. A corrosion inhibition mechanism is proposed as a model explaining the behavior of R in terms of water diffusion across a hydrophobic inhibitor barrier. Some consequences of this model bear on the effects of metallurgy on inhibitor effectiveness and rationalize the occurrence of pitting on some steels and its absence on others. Smail amplitude polarization measurements can therefore be used effectively in inhibitor studies, even if the classical assumptions of linearity and Tafel behavior are not fulfilled.Keywords
This publication has 1 reference indexed in Scilit:
- Carbonyl compounds as corrosion inhibitors for mild steel in HCl solutionsCorrosion Science, 1984