Adaptive Ankle Exoskeleton Control: Validation Across Diverse Walking Conditions
- 22 June 2021
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 3 (3) , 801-812
Abstract
Ankle exoskeletons hold potential to augment human walking ability, yet their use in free-living environments has been limited by the absence of practical and effective control strategies that can appropriately adapt to variable terrain. To address this challenge, we derived a novel analytical ankle joint moment estimation model using custom wearable sensors and developed an exoskeleton control scheme to adapt assistance proportional to the biological plantar-flexor moment in real-time for unimpaired individuals and individuals with disabilities who are able to ambulate independently. We validated the controller during level, 5° incline and decline walking, each at multiple speeds; stair ascent; stair descent; and 90° turning (88 ± 3% average accuracy, R = 0.96 ± 0.01 average correlation coefficient). This study demonstrates the ability of the controller to accurately adapt assistance in unimpaired individuals across a wide variety of walking conditions without the need for walking condition classification or real-time assessment of muscle activity. Clinical feasibility testing in four individuals with cerebral palsy suggests that this control method holds promise for incline and stair walking in individuals with mild-to-severe impairment. This ankle-moment-adaptive control system can be used to prescribe ankle exoskeleton assistance that adapts in real-time across the tested conditions.Keywords
Funding Information
- NSF (1756029)
- Arizona Biomedical Research Centre (ADHS18-198864)
- Northern Arizona University Institutional Review Board
This publication has 39 references indexed in Scilit:
- Reducing the energy cost of human walking using an unpowered exoskeletonNature, 2015
- Assessment of the ankle muscle co-contraction during normal gait: A surface electromyography studyJournal of Electromyography and Kinesiology, 2015
- Review of assistive strategies in powered lower-limb orthoses and exoskeletonsRobotics and Autonomous Systems, 2015
- Control strategies for active lower extremity prosthetics and orthotics: a reviewJournal of NeuroEngineering and Rehabilitation, 2015
- Children with cerebral palsy have greater stochastic features present in the variability of their gait kinematicsResearch in Developmental Disabilities, 2013
- Mechanics and energetics of level walking with powered ankle exoskeletonsJournal of Experimental Biology, 2008
- Plantar pressure differences between obese and non-obese adults: a biomechanical analysisInternational Journal of Obesity, 2001
- Patterns of weight distribution under the metatarsal headsThe Journal of Bone and Joint Surgery. British volume, 1999
- Strategies for Increasing Walking Speed in Diplegic Cerebral PalsyJournal of Pediatric Orthopaedics, 1996
- Abduction-adduction moments at the knee during stair ascent and descentJournal of Biomechanics, 1996