Daily moderate-to-vigorous physical activity (MVPA) evaluations based on absolute cutoffs from accelerometer data are inappropriate for characterising physical capacities, given inter-individual variability. We developed a new method that evaluates an individual's MVPA boundary without difficult exhaustion tests by estimating the critical intensity in daily activities using accelerometers. Thirty-five participants with varying fitness levels wore a 3-axis accelerometer for 3-6 weeks. They performed a sub-maximal incremental walking test on a 15%-inclined treadmill, where the speed at 4 mmol·L-1 (S4 mM) was computed. A two-parameter critical intensity model was fitted to Dynamic Body Acceleration (DBA) records using quantile regression. The critical DBA (DBAC) was computed from this model and compared with the traditional absolute cutoff for MVPA. DBAC was a strong predictor of S4 mM (r2 = 0.788) and, compared with individual characterisation, the traditional MVPA analysis resulted in a mean absolute error of 10:37 min/day (118%) and 12:07 min/day (26%) for time spent in vigorous and moderate activity, respectively. In conclusion, the individual DBAC computed from daily life activities without controlled laboratory tests accurately represents the severe intensity domain boundary. This method enhances the current absolute cutoff MVPA classification, which fails to accurately represent the time spent in intensity domains with individual physiological meanings.Keywords
Funding Information
- French National Agency
- USMB Fondation (CritActim)
This publication has 48 references indexed in Scilit:
- Invited review: The speed-duration relationship across the animal kingdomComparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology, 2023
- Critical power is the severe intensity domain boundary, not a power output that can be maintained “for a very long time without fatigue”European Journal of Applied Physiology, 2022
- A critical review of critical powerEuropean Journal of Applied Physiology, 2022
- Power profiling and the power-duration relationship in cycling: a narrative reviewEuropean Journal of Applied Physiology, 2021
- Identification of maximal lactate steady state by a short lactate minimum test in walkingScience & Sports, 2021
- An Examination and Critique of Current Methods to Determine Exercise IntensitySports Medicine, 2020
- Sedentary behaviour and risk of all-cause, cardiovascular and cancer mortality, and incident type 2 diabetes: a systematic review and dose response meta-analysisEuropean Journal of Epidemiology, 2018
- Validity and reliability of critical power field testingEuropean Journal of Applied Physiology, 2014
- Validation and comparison of ActiGraph activity monitorsJournal of Science and Medicine in Sport, 2011
- Assessing the development and application of the accelerometry technique for estimating energy expenditureComparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology, 2011