Evaluation of Outpatients Experiencing Implantable Cardioverter Defibrillator Shocks Associated with Minimal Symptoms
Authors:
- 1 May 1994
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (5) , 938-943
Abstract
Patients receiving minimally symptomatic shocks from their implantable cardioverter defibrillators were studied prospectively using transtelephonic ECC loop monitoring. The time course to the first subsequent shock was evaluated. Twenty‐nine consecutive patients who received a shock preceded by mild palpitations or no symptoms were given a transtelephonic ECG loop monitor and instructed to activate the monitor if a subsequent shock occurred. Kaplan‐Meier analysis was used to quantitate the time to first shock during the study period. The point estimate ± standard error of patients receiving a shock during the study period was 31%± 9% at 30 days, 41%± 9% at 60 days, and 60%± 9% at 120 days. The ECG was successfully transmitted in 7 of 13 patients who had shocks in the 60‐day monitoring period, and demonstrated inappropriate shocks in 6 of 7. Determination of the cause of shock led to a change in subsequent management in all 7 patients. We conclude that the incidence of inappropriate shocks may be higher than estimated previously in patients with minimal symptoms prior to the shock. There are thousands of patients with implantable cardioverter defibrillators that have no storage function for treated tachycardias; transtelephonic ECG loop monitoring can determine the cause of implantable cardioverter defibrillator discharge in these patients, and the diagnosis is invaluable in their management.Keywords
This publication has 8 references indexed in Scilit:
- Utility of transtelephonic ECG monitoring in evaluating discharges from a third-generation implantable cardioverter defibrillatorJournal of Electrocardiology, 1993
- Electrocardiographically Documented Unnecessary, Spontaneous Shocks in 241 Patients With Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1992
- Accuracy of Rhythm Classification Using a Data Log System in Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1991
- Clinical Performance of the Implantable Cardioverter Defibrillator: Electrocardiographic Documentation of 101 Spontaneous DischargesPacing and Clinical Electrophysiology, 1991
- Cardiac rhythm precipitating automatic implantable cardioverter-defibrillator discharge in outpatients as detected from transtelephonic electrocardiographs recordingsThe American Journal of Cardiology, 1991
- Actuarial Incidence and Pattern of Occurrence of Shocks Following Implantation of the Automatic Implantable Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1989
- The automatic implantable cardioverter defibrillator: Efficacy, complications and survival in patients with malignant ventricular arrhythmiasJACC, 1988
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985