Donor and surgical risk factors for primary graft failure following Descemet's stripping automated endothelial keratoplasty in Asian eyes
Authors:
- CajucomCACajucom
- Jod MehtaJod Mehta
Open Access
- 1 October 2011
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 5, 1503-1508
Abstract
Background: Descemet's stripping automated endothelial keratoplasty (DSAEK) has been shown to have superior refractive and visual results compared with penetrating keratoplasty, but higher rates of primary graft failure (PGF). This paper presents donor and surgical risk factors for PGF in DSAEK cases in Asian eyes. Design: Retrospective case-control study. Participants: All consecutive patients who underwent DSAEK at a tertiary referral teaching hospital from March 2006–December 2008. Methods: Donor details analyzed were: age of donor, cause of donor death, death to harvesting time, donor storage time, distribution distance of tissue, preoperative endothelial cell count. Surgical factors analyzed were: donor diameter, donor thickness, and method of donor insertion. These risk factors in cases of PGF were compared with patients with successful DSAEK as the control group. Main outcome measure: PGF. Results: A total of 124 DSAEK procedures were performed. Six DSAEK procedures (five eyes of five patients; one eye with two failures) resulted in PGF (4.8%). Significant risk factors were found for PGF to include graft insertion using a folding technique (odds ratio [OR], 34.03; 95% confidence interval [CI], 3.75–314.32; P = 0.0017) and a small donor diameter (OR, 39.94; 95% CI, 2.18–732.17; P = 0.013). Conclusion: The results of this study suggest that in Asian eyes with shallow anterior chambers, surgical trauma relating to the technique of donor insertion, and the use of a small donor are major risk factors for PGF following DSAEK.Keywords
This publication has 24 references indexed in Scilit:
- Descemet's Stripping Endothelial Keratoplasty: Safety and OutcomesOphthalmology, 2009
- Endothelial Cell Loss after Descemet Stripping with Endothelial KeratoplastyOphthalmology, 2008
- Glide insertion technique for donor cornea lenticule during Descemet's stripping automated endothelial keratoplastyJournal of Cataract & Refractive Surgery, 2007
- Experience and 12-Month Results of Descemet-Stripping Endothelial Keratoplasty (DSEK) with a Small-Incision TechniqueCornea, 2007
- Descemet’s Stripping with Endothelial KeratoplastyOphthalmology, 2006
- Descemet's stripping with endothelial keratoplasty in 200 eyesJournal of Cataract & Refractive Surgery, 2006
- Primary Corneal Graft FailureArchives of Ophthalmology (1950), 1995
- Primary Graft Failure: A Case Control Investigation of a Purported ClusterCornea, 1994
- Graft failure after penetrating keratoplastySurvey of Ophthalmology, 1990
- Donor Failure After Corneal Transplantation SurgeryCornea, 1988