Method for Measuring Mixed Field Radiation Levels Relevant for SEEs at the LHC
Authors:
- 16 February 2012
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 59 (4) , 1040-1047
Abstract
At the Large Hadron Collider (LHC), installed electronics will be exposed to a radiation field of mixed particles over a wide range of energies. While Monte Carlo transport codes can be used for calculations and predictions of radiation levels, the complex operation and layout of the LHC accelerator give rise to unavoidable uncertainties. Dedicated radiation monitors are therefore installed in locations of the electronics to provide an online measurement of the radiation levels pertinent to single-event upsets (SEUs). This paper addresses the method that has been applied to calibrate these radiation monitors for their use in mixed radiation fields. New irradiation tests to determine the sensitivity to neutrons from a few megaelectronvolts to 20 MeV will be presented along with additional irradiation tests with high-energy protons .Keywords
This publication has 13 references indexed in Scilit:
- Design, implementation and first measurements with the Medipix2-MXR detector at the Compact Muon Solenoid experimentJournal of Instrumentation, 2011
- FLUKA Simulations for SEE Studies of Critical LHC Underground AreasIEEE Transactions on Nuclear Science, 2011
- LHC Accelerator Design Studies on the Example of Passive AbsorbersNuclear Technology, 2009
- The physics of the FLUKA code: Recent developmentsAdvances In Space Research, 2007
- ENDF/B-VII.0: Next Generation Evaluated Nuclear Data Library for Nuclear Science and TechnologyNuclear Data Sheets, 2006
- Quasi-monoenergetic neutron reference fields in the energy range from thermal to 200 MeVRadiation Protection Dosimetry, 2004
- Radiation effects testing facilities in PSI during implementation of the Proscan project2003
- Computational method to estimate Single Event Upset rates in an accelerator environmentNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- Neutron radiation of an electronic sensor using coincidence method for an active dosimeterNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999
- Nuclear physics of cosmic ray interaction with semiconductor materials: Particle-induced soft errors from a physicist's perspectiveIBM Journal of Research and Development, 1996