Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children
Authors:
Open Access
- 11 December 2020
- journal article
- research article
- Published by Springer Nature in Pediatric Radiology
- Vol. 51 (8) , 1503-1517
Abstract
Cardiovascular MRI has become an essential imaging modality in children with congenital heart disease (CHD) in the last 15–20 years. With use of appropriate sequences, it provides important information on cardiovascular anatomy, blood flow and function for initial diagnosis and post-surgical or -interventional monitoring in children. Although considered as more sophisticated and challenging than CT, in particular in neonates and infants, MRI is able to provide information on intra- and extracardiac haemodynamics, in contrast to CT. In recent years, four-dimensional (4-D) flow MRI has emerged as an additional MR technique for retrospective assessment and visualisation of blood flow within the heart and any vessel of interest within the acquired three-dimensional (3-D) volume. Its application in young children requires special adaptations for the smaller vessel size and faster heart rate compared to adolescents or adults. In this article, we provide an overview of 4-D flow MRI in various types of complex CHD in neonates and infants to demonstrate its potential indications and beneficial application for optimised individual cardiovascular assessment. We focus on its application in clinical routine cardiovascular workup and, in addition, show some examples with pathologies other than CHD to highlight that 4-D flow MRI yields new insights in disease understanding and therapy planning. We shortly review the essentials of 4-D flow data acquisition, pre- and post-processing techniques in neonates, infants and young children. Finally, we conclude with some details on accuracy, limitations and pitfalls of the technique.Keywords
Funding Information
- University of Zurich
This publication has 59 references indexed in Scilit:
- 4D flow MRIJournal of Magnetic Resonance Imaging, 2012
- Rapid Pediatric Cardiac Assessment of Flow and Ventricular Volume With Compressed Sensing Parallel Imaging Volumetric Cine Phase-Contrast MRIAmerican Journal of Roentgenology, 2012
- Preoperative and Postoperative MR Evaluation of Congenital Heart Disease in ChildrenRadiologic Clinics of North America, 2011
- Aortic Hemodynamics in Patients With and Without Repair of Aortic CoarctationInvestigative Radiology, 2011
- Time-resolved three-dimensional magnetic resonance velocity mapping of cardiovascular flow paths in volunteers and patients with Fontan circulationEuropean Journal of Cardio-Thoracic Surgery, 2011
- Flow measurement by cardiovascular magnetic resonance: a multi-centre multi-vendor study of background phase offset errors that can compromise the accuracy of derived regurgitant or shunt flow measurementsJournal of Cardiovascular Magnetic Resonance, 2010
- Flow‐sensitive four‐dimensional cine magnetic resonance imaging for offline blood flow quantification in multiple vessels: A validation studyJournal of Magnetic Resonance Imaging, 2010
- Improved SNR in phase contrast velocimetry with five‐point balanced flow encodingMagnetic Resonance in Medicine, 2010
- Time‐resolved 3D MR velocity mapping at 3T: Improved navigator‐gated assessment of vascular anatomy and blood flowJournal of Magnetic Resonance Imaging, 2007
- Noninvasive Quantification of Left-to-Right Shunt in Pediatric PatientsCirculation, 2001