Hybrid hysteresis current control and low‐frequency current harmonics mitigation based on proportional resonant in dc/ac inverter
Authors:
Open Access
- 1 November 2018
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 11 (13) , 2093-2101
Abstract
In the two‐stage photovoltaic (PV) micro‐inverters, the bipolar hysteresis current control with soft switching for dc/ac inverter can achieve fast dynamic response, robust current regulation and high efficiency even with higher switching frequency. To further reduce the switching losses, unipolar hysteresis current control is desirable. However, it suffers from zero‐crossing distortions and low frequency harmonics in the grid current. To solve those problems, this paper proposes a combined proportional resonant (PR) and hybrid hysteresis current control strategy. By investigating the reasons for zero‐crossing distortions, hybrid hysteresis current control is applied to enable bipolar modulation around the zero‐crossing zone and unipolar modulation in all other zones of the line period. At the same time, due to the wide hysteresis bands for soft switching, low output inductance and non‐negligible sampling intervals from the digital controller, there will be many low frequency harmonics in the spectrum of output inductor current which deteriorates the quality of power absorbed by the grid. Therefore, the PR control may be used as well to mitigate the low frequency harmonics. The theoretical analysis of the proposed solutions are explained in this paper. Detailed simulation and experimental results are presented to verify the feasibility of the proposed control strategy.Keywords
This publication has 16 references indexed in Scilit:
- Model Predictive Control of a Voltage-Source Inverter With Seamless Transition Between Islanded and Grid-Connected OperationsIEEE Transactions on Industrial Electronics, 2017
- Analysis and Optimization of Variable-Frequency Soft-Switching Peak Current Mode Control Techniques for MicroinvertersIEEE Transactions on Power Electronics, 2017
- Analysis, Design, and Implementation of a Quasi-Proportional-Resonant Controller for a Multifunctional Capacitive-Coupling Grid-Connected InverterIEEE Transactions on Industry Applications, 2016
- Lyapunov-Function and Proportional-Resonant-Based Control Strategy for Single-Phase Grid-Connected VSI With LCL FilterIEEE Transactions on Industrial Electronics, 2015
- Basic Principles of MPC for Power Converters: Bridging the Gap Between Theory and PracticeIEEE Industrial Electronics Magazine, 2015
- Analysis and Solution of Current Zero-Crossing Distortion With Unipolar Hysteresis Current Control in Grid-Connected InverterIEEE Transactions on Industrial Electronics, 2012
- Evaluation of the Main MPPT Techniques for Photovoltaic ApplicationsIEEE Transactions on Industrial Electronics, 2012
- Unipolar switched inverter low-frequency harmonics caused by switching delayIET Power Electronics, 2009
- Comparison of Photovoltaic Array Maximum Power Point Tracking TechniquesIEEE Transactions on Energy Conversion, 2007
- Current control techniques for three-phase voltage-source PWM converters: a surveyIEEE Transactions on Industrial Electronics, 1998