MC-ADD: A Geant4 code-generation and analysis workflow for radiation detector prototyping
Preprint
- 21 September 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
Monte Carlo simulations are widely used in radiation-detector development and characterization, but developing application-specific Geant4 simulations can require substantial knowledge of its C++ architecture and considerable implementation effort. We developed Monte Carlo Accessible Detector Development (MC-ADD), an open and extensible framework integrating graphical source and detector definition, automatic generation of editable Geant4 source files and macros, radiation transport, mesh-based geometries, and quantitative post-processing. The generated Geant4 application remains directly accessible for application-specific modifications. MC-ADD provides analysis of energy-deposition spectra, three-dimensional hit distributions, detection efficiencies, and voxelized absorbed-dose distributions. The framework was evaluated by comparing ideal and Gaussian-broadened simulated ¹³⁷Cs spectra with experimental measurements. Charged-particle transport was verified by comparing extrapolated α-particle ranges in air and water for ²⁴¹Am, ²²⁴Ra, and monoenergetic α-particle beams with reference databases. Mesh-based modeling was demonstrated using a spiral BCF-12 scintillating-fiber detector irradiated with ¹⁸F. The broadened ¹³⁷Cs spectrum reproduced the main measured spectral features, with a full-energy-peak efficiency of 15.794% ± 0.004%. Extrapolated α-particle ranges differed from reference values by less than 1% in both media, while simulated radionuclide spectra reproduced the principal α-emission energies. The spiral-fiber simulation produced a Compton-dominated deposited-energy spectrum for 511-keV photons and an absolute detection efficiency of 0.4198% ± 0.0007%. These results verify MC-ADD for selected photon and charged-particle transport configurations and demonstrate its use for mesh-based detector modeling. Optical transport, photodetector response, and electronics are not currently included.Keywords
This publication has 11 references indexed in Scilit:
- Development of small, cost‐efficient scintillating fiber detectors for automated synthesis of positron emission tomography radiopharmaceuticalsMedical Physics, 2024
- Investigation of dosimetric characteristics of radiochromic film in response to alpha particles emitted from Americium‐241Medical Physics, 2024
- Radiation Physics for Medical Physicists2016
- Overview of the FLUKA codeAnnals of Nuclear Energy, 2015
- AlfaMC: A fast alpha particle transport Monte Carlo codeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Gamos: A framework to do Geant4 simulations in different physics fields with an user-friendly interfaceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- TOPAS: An innovative proton Monte Carlo platform for research and clinical applicationsMedical Physics, 2012
- Comparative study of Lu3Al5O12:Pr3+ and Bi4Ge3O12 crystals for gamma – ray detectionProcedia Engineering, 2012
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- Introduction to Radiological Physics and Radiation Dosimetry1986