Clinical Accuracy of Cervicothoracic Pedicle Screw Placement
Authors:
- Gabriel Y. F. LeeGLGabriel Y. F. Lee
- Eric M. MassicotteEMEric M. Massicotte
- Y. Raja RampersaudYRY. Raja Rampersaud
- 1 February 2007
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 20 (1) , 25-32
Abstract
Posterior transpedicular fixation at the cervicothoracic junction (CTJ) is increasing in popularity. However, the clinical accuracy of pedicle screw placement at the CTJ has not been specifically assessed. Between January 2000 and July 2004, 60 consecutive patients underwent a variety of posterior spinal procedures necessitating pedicle screw placement at C7, T1, and T2. Thirty-two patients had cervicothoracic screws (3.5 to 4.5 mm) placed by an “open” technique (laminectomies or lamino-foraminotomies) and 28 patients with either a closed (before any decompression) 2-dimensional (n=19, fluoroscopy) or 3-dimensional (n=9, CT) computer-assisted technique. Screws were independently assessed for pedicle breach on postoperative CT and scored using a points-based classification system. The total number of screws placed was 86, 63 and 45 in the open, closed-2-dimensional and closed-3-dimensional groups, respectively. Overall, 61(70.9%), 51(81%), and 40(89%) screws were completely within the pedicle. In the open group, the majority of pedicle breaches were more than 2 mm [n=3 (4 mm)]. Screw violation occurred laterally 11/25(44%), medially 3/25(12%), inferiorly 7/25(28%), and superiorly 4/25(16%). In the closed technique, all breaches were lateral. Seventeen screws (n=11-2-dimensional, n=5-3-dimensional) breached the pedicle by a margin of less than 2 mm and 1 screw (2-dimensional) by 2 to 4 mm. Pedicle screw accuracy was significantly improved with computer-assisted techniques. However, there was no significant difference between the 2-dimensional and 3-dimensional techniques. For all patients, there were no clinically significant screw misplacements, nor any need for screw revision. Computer-assisted surgery allows for more accurate placement of pedicle screws at the CTJ. Although a higher proportion of major pedicular breaches occurred in the “open lamina/lamino-foraminotomy” group, no screws required revision in either group.Keywords
This publication has 26 references indexed in Scilit:
- Posterior Cervicothoracic Instrumentation in Spine TumorsSpine, 2004
- Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spineEuropean Spine Journal, 2004
- Thoracic Pedicle Screw Insertion Using a Transpedicular Drill GuideJournal of Spinal Disorders & Techniques, 2004
- Thoracic Pedicle: Surgical Anatomic Evaluation and RelationsJournal of Spinal Disorders, 2001
- Internal Morphology of Human Cervical PediclesSpine, 2000
- Use of Cervicothoracic Junction Pedicle Screws for Reconstruction of Complex Cervical Spine PathologySpine, 1998
- Pedicle Screw Fixation for Nontraumatic Lesions of the Cervical SpineSpine, 1997
- Posterior instrumentation of the unstable cervicothoracic spineJournal of Neurosurgery, 1996
- Placement of pedicle screws in the thoracic spine. Part IIJournal of Bone and Joint Surgery, 1995
- Spinal Disorders at the Cervicothoracic JunctionSpine, 1994