Abstract
Study Design: Between January 2002 and December 2005, a prospective study was performed with 14 patients. The patients had cervical diseases and received more than 1 segment anterior cervical corpectomies. Objectives: We investigated the effectiveness of the hollow cylindrical polymethyl methacrylate (PMMA) strut with the autograft for fusion and reconstruction of the cervical spine after multiplelevel cervical corpectomy. Summary of Background Data: We usually used the titanium mesh cage to reconstruct the cervical spine after cervical corpectomy. A significant number of poor outcomes were noted. Because the mesh cage is very hard, it sinks into the vertebral body without the cortex. It is also difficulty to assess the fusion status. Methods: A total of 14 patients (age range: 31 to 76 y) underwent anterior cervical corpectomy after fusion and reconstruction with cylindrical PMMA struts. Each patient was reinforced with anterior cervical plate fixation. Follow-up radiographic evaluation was comprised of plain lateral dynamic radiographs and computerized tomography (CT) scans. We evaluated the patients for cervical lordosis and vertebral body height on the basis of plain radiographs. The fusion status was evaluated with CT scans. Neurologic status was assessed preoperative and postoperatively using the Nurick's grading system. Results: The mean follow-up was 48.2 months (range: 28 to 70 mo). All patients showed spinal stability at 6 months follow-up on the basis of plain lateral dynamic radiograph results. Thirteen patients showed neurologic improvement with complete bony fusion in the 24-month reconstructed CT scans. There were no complications related to the hollow cylindrical PMMA strut. One patient had loosened screws and required a second operation. Conclusions: The cylindrical PMMA strut provides solid fusion and increased cervical lordosis and vertebral body height. There are few complications associated with the use of this strut, and neurologic recovery is satisfactory. The hollow cylindrical PMMA strut, combined with an anterior cervical plate, is a very successful surgical construct in these patients after long-segmental cervical corpectomy.Keywords
This publication has 43 references indexed in Scilit:
- Biomechanical Rationale for Using Polyetheretherketone (PEEK) Spacers for Lumbar Interbody Fusion–A Finite Element StudySpine, 2006
- PMMA versus Titanium Cage after Anterior Cervical Discectomy - A Prospective Randomized TrialCentral European Neurosurgery, 2006
- Complications and Long-Term Follow-Up Results in Titanium Mesh Cage Reconstruction After Cervical CorpectomyJournal of Spinal Disorders & Techniques, 2006
- Anterior CorpectomyJournal of Neurosurgery: Spine, 2006
- Use of cylindrical titanium mesh and locking plates in anterior cervical fusionJournal of Neurosurgery: Spine, 2001
- Primary stabilizing effect of interbody fusion devices for the cervical spine: an in vitro comparison between three different cage types and bone cementEuropean Spine Journal, 2000
- Anterior cervical allograft arthrodesis and instrumentation: Multilevel interbody grafting or strut graft reconstructionEuropean Spine Journal, 1997
- Central corpectomy for cervical spondylotic myelopathy: a consecutive series with long-term follow-up evaluationJournal of Neurosurgery, 1991
- Free Vascularized Fibular Strut Graft in the Treatment of KyphosisSpine, 1988
- Multiple Subtotal SomatectomySpine, 1984