Reduced incidence and economic cost of hardware removal after ankle fracture surgery: a 20-year nationwide registry study
Open Access
- 28 February 2020
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 91 (3) , 331-335
Abstract
Background and purpose — Open reduction and internal fixation (ORIF) is a treatment method for unstable ankle fractures. During recent years, scientific evidence has shed light on surgical indications as well as on hardware removal. We assessed the incidence and trends of hardware removal procedures following ORIF of ankle fractures. Patients and methods — The study covered all patients 18 years of age and older who had an ankle fracture treated with ORIF in Finland between the years 1997 and 2016. Patient data were obtained from the Finnish National Hospital Discharge Register. Results — 68,865 patients had an ankle fracture treated with ORIF in Finland during the 20-year study period between 1997 and 2016. A hardware removal procedure was performed on 27% of patients (n = 18,648). The incidence of hardware removal procedures after ankle fracture decreased from 31 (95% CI 29–32) per 100,000 person-years in the highest year 2001 (n = 1,247) to 13 (CI 12–14) per 100,000 person-years in 2016 (n = 593). Moreover, the proportion and number of removal operations performed within the first 3 months also decreased. The costs of removal procedures decreased from approximately €994,000 in 2001 to €472,600 in 2016. Interpretation — Removal of hardware after ankle surgery (ORIF) is a common operation with substantial costs. However, the incidence and cost of removals decreased during the study period, with a particular decrease in hardware removal operations within 3 months.Keywords
This publication has 24 references indexed in Scilit:
- Internal fixation of distal tibiofibular syndesmotic injuries: a systematic review with meta-analysisInternational Orthopaedics, 2013
- Determinants of outcome in operatively and non-operatively treated Weber-B ankle fracturesArchives of orthopaedic and trauma surgery, 2011
- To retain or remove the syndesmotic screw: a review of literatureArchives of orthopaedic and trauma surgery, 2010
- Outcome after Unstable Ankle Fracture: Effect of Syndesmotic StabilizationJournal of Orthopaedic Trauma, 2010
- Do orthopaedic surgeons need a policy on the removal of metalwork? A descriptive national survey of practicing surgeons in the United KingdomInjury, 2008
- Tissue restoration after resorption of polyglycolide and poly-laevo-lactic acid screwsThe Journal of Bone and Joint Surgery. British volume, 2005
- Routine Implant Removal after Fracture SurgeryThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Self-Reinforced Absorbable Screws in the Fixation of Displaced Ankle FracturesJournal of Orthopaedic Trauma, 1992
- Complications of metalwork removalInjury, 1992
- Observations on removal of metal implantsInjury, 1992