A COMPARATIVE STUDY OF STRENGTHENING AND RETROFITTING MEASURES FOR UNREINFORCED BRICK MASONRY MODEL UNDER CYCLIC TESTING
Authors:
- 1 November 2004
- journal article
- research article
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 8 (6) , 839-863
Abstract
An experimental study on half-scale brick-masonry models with different strengthening and retrofitting measures has been studied under cyclic loading in a quasi-static test facility. The strengthening measures undertaken for the studies axe the horizontal bond beam at the lintel and sill level with a combination of vertical reinforcement at corners and openings. The retrofitting measures studied are grouting with epoxy-sand-mortar and cement-grout-injection with welded wire mesh in the cracked region. The tests reveal that the horizontal bond beam at lintel level with vertical reinforcement is effective in reducing the cracking above the lintel level. The insertion of an additional sill-band signi-ficantly reduces the cracking in walls. The epoxy-sand-mortar techniques for retrofitting of cracked regions prove to be effective enough to restore the initial strength, stiffness and deformation capacity. Although specimen retrofitted with cement-grout-injection with welded wire mesh is effective to regain the ultimate strength yet the brittle failure is observed as the specimen is stressed beyond the elastic limit.Keywords
This publication has 5 references indexed in Scilit:
- Earthquake-Resistant Design of Masonry Buildings1999
- 8. Seismic Damage Indices for Concrete Structures: A State‐of‐the‐Art ReviewEarthquake Spectra, 1995
- Seismic Design of Reinforced Concrete and Masonry Buildings1992
- Reliability of Concrete Frames Damaged by EarthquakesJournal of Structural Engineering, 1987
- Analytical Modeling of Hysteretic Behavior of R/C FramesJournal of Structural Engineering, 1987