Predicting the Best Fit: A Comparison of Response Surface Models for Midazolam and Alfentanil Sedation in Procedures With Varying Stimulation
Authors:
- 1 August 2016
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 123 (2) , 299-308
Abstract
BACKGROUND: Selecting an effective dose of sedative drugs in combined upper and lower gastrointestinal endoscopy is complicated by varying degrees of pain stimulation. We tested the ability of 5 response surface models to predict depth of sedation after administration of midazolam and alfentanil in this complex model. The procedure was divided into 3 phases: esophagogastroduodenoscopy (EGD), colonoscopy, and the time interval between the 2 (intersession).METHODS: The depth of sedation in 33 adult patients was monitored by Observer Assessment of Alertness/Scores. A total of 218 combinations of midazolam and alfentanil effect-site concentrations derived from pharmacokinetic models were used to test 5 response surface models in each of the 3 phases of endoscopy. Model fit was evaluated with objective function value, corrected Akaike Information Criterion (AICc), and Spearman ranked correlation. A model was arbitrarily defined as accurate if the predicted probability is alfin the Hierarchy model improved model fit.CONCLUSIONS: The reduced Greco model had the lowest objective function value and AICc and thus the best fit. This model was reliable with acceptable predictive ability based on adequate clinical correlation. We suggest that this model has practical clinical value for patients undergoing procedures with varying degrees of stimulation.Keywords
This publication has 38 references indexed in Scilit:
- Response Surface Modeling of the Interaction between Propofol and SevofluraneAnesthesiology, 2009
- Minor adverse events of colonoscopy on ambulatory patients: the impact of moderate sedationEuropean Journal of Gastroenterology & Hepatology, 2009
- An Evaluation of Remifentanil Propofol Response Surfaces for Loss of Responsiveness, Loss of Response to Surrogates of Painful Stimuli and Laryngoscopy in Patients Undergoing Elective SurgeryAnesthesia & Analgesia, 2008
- Performance of AEP Monitor/2-derived composite index as an indicator for depth of sedation with midazolam and alfentanil during gastrointestinal endoscopyEuropean Journal of Anaesthesiology, 2007
- Opioid–Volatile Anesthetic SynergyAnesthesiology, 2006
- Propofol Reduces Perioperative Remifentanil Requirements in a Synergistic MannerAnesthesiology, 2003
- Response Surface Modeling of Remifentanil–Propofol Interaction on Cardiorespiratory Control and Bispectral IndexAnesthesiology, 2003
- Triple Anesthetic CombinationAnesthesia & Analgesia, 1994
- Does Opioid “Anesthesia” Exist?Anesthesiology, 1990
- Population Pharmacokinetics of AlfentanilAnesthesiology, 1987