Minimally Invasive Robotic Versus Open Fluoroscopic-guided Spinal Instrumented Fusions
Authors:
- Ki-Jeong KimKKKi-Jeong Kim
- Tae-Ahn JahngTJTae-Ahn Jahng
- Hyun-Jib KimHKHyun-Jib Kim
Top Cited Papers
- 15 March 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 42 (6) , 353-358
Abstract
A prospective randomized clinical trial. To compare the impact of robotic guidance in a minimally invasive spine surgery (MIS) to a fluoroscopy-guided open approach in lumbar fusions. MIS requires a protracted learning curve and excessively exposes the patient and surgical team to harmful radiation. Robotic-guidance has been shown to improve accuracy and radiation in most studies, but there is conflicting prospective data. Patients indicated to undergo a 1 or 2 level spinal fusion were randomized between robotic-guided MIS (RO) and fluoroscopic-guided open surgery (FA). Patient demographics and outcomes were recorded. Thirty patients were recruited to each arm. Average age was 66.7 years, 71.5% were females, and average body mass index was 25.2. Thirty-five levels were instrumented with 130 pedicle screws in RO versus 40 levels with 140 screws in FA, or 4.3 and 4.7 screws per surgery, respectively. Use of fluoroscopy was 3.5 versus 13.3 seconds in the RO and FA respectively (P < 0.001). C-arm output in mSv was 0.13 versus 0.27 in the RO and FA respectively (P = 0.015). By thermoluminescent dosimeters, the average per-screw radiation in the RO arm was 37.5% of that in the FA arm, demonstrating a mean reduction of 62.5% in use of radiation. There was no difference in the improvement in Visual Analog Scale scores for back and leg or the Oswestry Disability Index. All screws were accurate in RO whereas two screws breached (>2 mm and >4 mm) in FA (P = 0.500). One proximal facet violation occurred in the study, it was in FA (P = 1.000). The average distance from the proximal facets was 5.8 versus 4.6 mm in the RO and FA respectively (P < 0.001). The average length of stay was 6.8 versus 9.4 days in RO compared with FA (P = 0.020). MIS using robotic-guidance significantly reduced radiation exposure and length of stay. Patient outcomes were not affected by the surgical technique. Level of Evidence: 1Keywords
This publication has 32 references indexed in Scilit:
- Comparative Effectiveness of Minimally Invasive Versus Open Transforaminal Lumbar Interbody FusionJournal of Spinal Disorders & Techniques, 2011
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Minimally invasive or open transforaminal lumbar interbody fusion as revision surgery for patients previously treated by open discectomy and decompression of the lumbar spineEuropean Spine Journal, 2010
- Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studiesEuropean Spine Journal, 2010
- Comparison of one-level minimally invasive and open transforaminal lumbar interbody fusion in degenerative and isthmic spondylolisthesis grades 1 and 2European Spine Journal, 2010
- Minimally Invasive Approach versus Traditional Open Approach for One Level Posterior Lumbar Interbody Fusionmin - Minimally Invasive Neurosurgery, 2010
- Minimally invasive versus open transforaminal lumbar interbody fusionSurgical Neurology International, 2010
- The challenges faced in the design, conduct and analysis of surgical randomised controlled trialsTrials, 2009
- Minimally invasive versus open transforaminal lumbar interbody fusion: evaluating initial experienceInternational Orthopaedics, 2008
- Comparison of One-Level Posterior Lumbar Interbody Fusion Performed With a Minimally Invasive Approach or a Traditional Open ApproachSpine, 2007