In vivo diffusion MRI of the human heart using a 300 mT/m gradient system
Authors:
- Maryam AfzaliMAMaryam Afzali
- Lars MuellerLMLars Mueller
- Sam CoveneySCSam Coveney
- Fabrizio FasanoFFFabrizio Fasano
- Christopher John EvansCEChristopher John Evans
- Maria EngelMEMaria Engel
- Irvin TehITIrvin Teh
- Erica Dall'ArmellinaEDErica Dall'Armellina
- Derek K. JonesDJDerek K. Jones
- Jürgen E. SchneiderJSJürgen E. Schneider
Open Access
- 22 April 2024
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 92 (3) , 1022-1034
Abstract
Purpose: This work reports for the first time on the implementation and application of cardiac diffusion‐weighted MRI on a Connectom MR scanner with a maximum gradient strength of 300 mT/m. It evaluates the benefits of the increased gradient performance for the investigation of the myocardial microstructure.Methods: Cardiac diffusion‐weighted imaging (DWI) experiments were performed on 10 healthy volunteers using a spin‐echo sequence with up to second‐ and third‐order motion compensation ( and ) and , and 1000 (twice the commonly used on clinical scanners). Mean diffusivity (MD), fractional anisotropy (FA), helix angle (HA), and secondary eigenvector angle (E2A) were calculated for b = [100, 450] and b = [100, 1000] for both and .Results: The MD values with are slightly higher than with with for and for . A reduction in MD is observed by increasing the from 450 to 1000 ( for and for ). The difference between FA, E2A, and HA was not significant in different schemes ().Conclusion: This work demonstrates cardiac DWI in vivo with higher b‐value and higher order of motion compensated diffusion gradient waveforms than is commonly used. Increasing the motion compensation order from to and the maximum b‐value from 450 to 1000 affected the MD values but FA and the angular metrics (HA and E2A) remained unchanged. Our work paves the way for cardiac DWI on the next‐generation MR scanners with high‐performance gradient systems.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EP/M029778/1)
- Wellcome Trust (096646/Z/11/Z, 104943/Z/14/Z, 219536/Z/19/Z)
- British Heart Foundation (PG/19/1/34076)
This publication has 52 references indexed in Scilit:
- Evaluation of optimized inversion‐recovery fat‐suppression techniques for T2‐weighted abdominal MR imagingJournal of Magnetic Resonance Imaging, 2008
- Diffusion imaging of the in vivo heart using spin echoes–considerations on bulk motion sensitivityMagnetic Resonance in Medicine, 2007
- Formal characterization and extension of the linearized diffusion tensor modelHuman Brain Mapping, 2004
- Time‐optimal multidimensional gradient waveform design for rapid imagingMagnetic Resonance in Medicine, 2003
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Two‐component diffusion tensor MRI of isolated perfused heartsMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 TMagnetic Resonance in Medicine, 1998
- Concomitant gradient terms in phase contrast MR: Analysis and correctionMagnetic Resonance in Medicine, 1998
- Correction for geometric distortion in echo planar images from B0 field variationsMagnetic Resonance in Medicine, 1995