Low Initial Adherence with Flash Glucose Monitoring is Not a Predictor of Long-Term Glycemic Outcomes: Longitudinal Analysis of the Association Between Experience, Adherence, and Glucose Control for FreeStyle Libre Users
Authors:
Open Access
- 22 May 2023
- journal article
- research article
- Published by Springer Nature in Diabetes Therapy
- Vol. 14 (7) , 1231-1240
Abstract
Introduction Frequent scanning of FreeStyle Libre (FSL) flash glucose monitoring sensors is known to be important whilst wearing an active sensor, but adherence to sensor reapplication is also critical to effective glucose monitoring. We report novel measures of adherence for users of the FSL system and their association with improvements in metrics of glucose control. Methods Anonymous data were extracted for 1600 FSL users in the Czech Republic with ≥ 36 completed sensors from October 22, 2018 to December 31, 2021. “Experience” was defined by the number of sensors used (1–36 sensors). “Adherence” was defined by time between the end of one sensor and the start of the next (gap time). User adherence was analyzed for four experience levels after initiating FLASH; Start (sensors 1–3); Early (sensors 4–6); Middle (sensors 19–21); End (sensors 34–36). Users were split into two adherence levels based on mean gap time during Start period, “low” (> 24 h, n = 723) and “high” (≤ 8 h, n = 877). Results Low-adherence users reduced their sensor gap times significantly: 38.5% applied a new sensor within 24 h during sensors 4–6, rising to 65.0% by sensors 34–36 (p < 0.001). Improved adherence was associated with increased %TIR (time in range; mean + 2.4%; p < 0.001), reduced %TAR (time above range; mean − 3.1%; p < 0.001), and reduced glucose coefficient of variation (CV; mean − 1.7%; p < 0.001). Conclusions With experience, FSL users became more adherent in sensor reapplication, with associated increases in %TIR, and reductions in %TAR and glucose variability.Keywords
Funding Information
- Ministerstvo Zdravotnictví Ceské Republiky (RVO-VFN00064165)
- Abbott Diabetes Care
This publication has 12 references indexed in Scilit:
- Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With DiabetesJournal of Diabetes Science and Technology, 2020
- Effect of Flash Glucose Monitoring on Glycemic Control, Hypoglycemia, Diabetes-Related Distress, and Resource Utilization in the Association of British Clinical Diabetologists (ABCD) Nationwide AuditDiabetes Care, 2020
- Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in RangeDiabetes Care, 2019
- Need for Regulatory Change to Incorporate Beyond A1C Glycemic MetricsDiabetes Care, 2018
- Real-world flash glucose monitoring patterns and associations between self-monitoring frequency and glycaemic measures: A European analysis of over 60 million glucose testsDiabetes Research and Clinical Practice, 2018
- International Consensus on Use of Continuous Glucose MonitoringDiabetes Care, 2017
- Continuous Glucose Monitoring Versus Usual Care in Patients With Type 2 Diabetes Receiving Multiple Daily Insulin InjectionsAnnals of Internal Medicine, 2017
- Effect of Continuous Glucose Monitoring on Glycemic Control in Adults With Type 1 Diabetes Using Insulin InjectionsJAMA, 2017
- Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trialThe Lancet, 2016
- The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring SystemDiabetes Technology & Therapeutics, 2015