Cicerone: stereotactic neurophysiological recording and deep brain stimulation electrode placement software system
- 1 January 2007
- book chapter
- Published by Springer Nature
- Vol. 97, 561-567
Abstract
Stereotactic neurosurgery and neurophysiological microelectrode recordings in both humans and monkeys are typically done with conventional 2D atlases and paper records of the stereotactic coordinates. This approach is prone to error because the brain size, shape, and location of subcortical structures can vary between subjects. Furthermore, paper record keeping is inefficient and limits opportunities for data visualization. To address these limitations, we developed a software tool (Cicerone) that enables interactive 3D visualization of co-registered magnetic resonance images (MRI), computed tomography (CT) scans, 3D brain atlases, neurophysiological microelectrode recording (MER) data, and deep brain stimulation (DBS) electrode(s) with the volume of tissue activated (VTA) as a function of the stimulation parameters. The software can be used in pre-operative planning to help select the optimal position on the skull for burr hole (in humans) or chamber (in monkeys) placement to maximize the likelihood of complete microelectrode and DBS coverage of the intended anatomical target. Intra-operatively, Cicerone allows entry of the stereotactic microdrive coordinates and MER data, enabling real-time interactive visualization of the electrode location in 3D relative to the surrounding neuroanatomy and neurophysiology. In addition, the software enables prediction of the VTA generated by DBS for a range of electrode trajectories and tip locations. In turn, the neurosurgeon can use the combination of anatomical (MRI/CT/3D brain atlas), neurophysiological (MER), and electrical (DBS VTA) data to optimize the placement of the DBS electrode prior to permanent implantation.Keywords
This publication has 26 references indexed in Scilit:
- Sources and effects of electrode impedance during deep brain stimulationClinical Neurophysiology, 2006
- Role of electrode design on the volume of tissue activated during deep brain stimulationJournal of Neural Engineering, 2005
- Computer-aided placement of deep brain stimulators: from planningto intraoperative guidanceIEEE Transactions on Medical Imaging, 2005
- Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulationClinical Neurophysiology, 2005
- Usefulness of an Intraoperative Electrophysiological Navigator System for Subthalamic Nucleus Surgery in Parkinson’s DiseaseStereotactic and Functional Neurosurgery, 2005
- Correspondence of microelectrode mapping with magnetic resonance imaging for subthalamic nucleus proceduresSurgical Neurology, 2005
- Chronic implantation of deep brain stimulation leads in animal models of neurological disordersJournal of Neuroscience Methods, 2005
- Deep brain stimulation for Parkinson’s diseaseCurrent Opinion in Neurobiology, 2003
- Three-dimensional database of subcortical electrophysiology for image-guided stereotactic functional neurosurgeryIEEE Transactions on Medical Imaging, 2003
- Combined (Thalamotomy and Stimulation) Stereotactic Surgery of the VIM Thalamic Nucleus for Bilateral Parkinson DiseaseStereotactic and Functional Neurosurgery, 1987