X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study
- 28 February 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 33 (1) , 110-118
Abstract
: OBJECTIVES: To compare a standard protocol using chest computed tomography (CT) to a non-irradiant protocol involving a low-cost portable 3D scanner and magnetic resonance imaging (MRI) for all pectus deformities based on the Haller index (HI). METHODS: From April 2019 to March 2020, all children treated for pectus excavatum or carinatum at our institution were evaluated by chest CT, 3D scanning (iPad with Structure Sensor and Captevia—Rodin4D) and MRI. The main objectives were to compare the HI determined by CT or MRI to a derived index evaluated with 3D scanning, the external Haller index (EHI). The secondary objectives were to assess the inter-rater variability and the concordance between CT and MRI for the HI and the correction index. RESULTS: Eleven patients were evaluated. We identified a strong correlation between the HI with MRI and the EHI (Pearson correlation coefficient = 0.900; P < 0.001), with a strong concordance between a radiologist and a non-radiologist using intra-class correlation for the HI with MRI (intra-class correlation coefficient = 0.995; [0.983; 0.999]) and the EHI (intra-class correlation coefficient = 0.978; [0.823; 0.995]). We also identified a marked correlation between the HI with CT and the EHI (Pearson coefficient = 0.855; P = 0.002), with a strong inter-rater concordance (intra-class correlation coefficient = 0.975; [0.901; 0.993]), a reliable concordance between CT and MRI for the HI and the correction index (Pearson coefficient = 0.886; P = 0.033). CONCLUSIONS: Non-irradiant pectus deformity assessment is possible in clinical practice, replacing CT with MRI and 3D scanning as a possible readily-accessible monitoring tool.Keywords
This publication has 28 references indexed in Scilit:
- Development and validation of the Pectus Carinatum Body Image Quality of Life (PeCBI-QOL) questionnaireJournal of Pediatric Surgery, 2019
- The incidence of Marfan syndrome and cardiac anomalies in patients presenting with pectus deformitiesJournal of Pediatric Surgery, 2019
- Preoperative multimodality imaging of pectus excavatum: State of the art review and call for standardizationEuropean Journal of Radiology, 2019
- Impact of pectus excavatum on cardiac morphology and function according to the site of maximum compression: effect of physical exertion and respiratory cycleEuropean Heart Journal - Cardiovascular Imaging, 2019
- Outcomes, quality of life, and long-term results after pectus repair from around the globeSeminars in Pediatric Surgery, 2018
- Imaging of congenital chest wall deformitiesBritish Journal of Radiology, 2016
- Z-Type Pattern Pectus Excavatum/Carinatum in A Case of Noonan SyndromeThe Annals of Thoracic Surgery, 2015
- Anatomical, Histologic, and Genetic Characteristics of Congenital Chest Wall DeformitiesSeminars in Thoracic and Cardiovascular Surgery, 2009
- Less extensive techniques for repair of pectus carinatum: The undertreated chest deformity1Journal of the American College of Surgeons, 2004
- A pilot study of the impact of surgical repair on disease-specific quality of life among patients with pectus excavatumJournal of Pediatric Surgery, 2003