Effective performance of contrast enhanced SPACE imaging in clearly depicting the margin of pituitary adenoma
- 19 September 2014
- journal article
- Published by Springer Nature in Pituitary
- Vol. 18 (4) , 480-486
Abstract
The aim of this study is to determine if contrast enhanced (CE) sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) images can provide clearer pituitary adenoma margin than conventional CE T1-weighted spin echo (T1-SE) sequence for cavernous sinus (CS) invasion evaluation. 21 healthy volunteers were preformed with SPACE scans before and after administration of gadopentetate dimeglumine at different time points (1, 7 and 13 min). Signal intensity (SI) of regions of interest was plotted in SI/time curves for bilateral CS, pituitary and temporal lobe. 35 patients with pituitary adenoma (≥1 cm) were performed CE T1-SE and CE SPACE scans. Two observers made the visual assessment of the tumor margin delineation and CS invasion evaluation on both SPACE and T1-SE images. Surgical findings were compared with the invasion assessment results. At 1, 7 and 13 min after enhancement, SI of left CS increased 6.7, 9.5 and 11.2 % respectively compared with unenhanced images (all p < 0.05). Right CS increased 7.2, 9.3 and 11.3 % (all p < 0.05 %). Within pituitary, a decline (6.3 %, p < 0.05) of SI was measured at 1 min after enhancement. CE SPACE performed superior to those of CE T1-SE sequence in visual assessment of tumor edge (assessment score, 1.66 ± 0.42 vs. 1.23 ± 0.65, p < 0.05), as well as the specificity (86.8 vs. 66.0 %, p < 0.05) and accuracy(85.7 vs. 68.6 %, p < 0.05) for CS invasion evaluation. CE SPACE could provide better contrast of pituitary adenoma with surrounding CS and clear demonstration of tumor edge for CS invasion evaluation than conventional CE T1-SE sequence.Keywords
This publication has 15 references indexed in Scilit:
- Magnetic resonance imaging appearance of the medial wall of the cavernous sinus for the assessment of cavernous sinus invasion by pituitary adenomasJournal Of Neuroradiology, 2013
- Endoscopic endonasal surgery for giant pituitary adenomas: advantages and limitationsJournal of Neurosurgery, 2013
- Three-dimensional sampling perfection with application-optimised contrasts using a different flip angle evolutions sequence for routine imaging of the spine: preliminary experienceBritish Journal of Radiology, 2012
- Advances in pituitary imaging technology and future prospectsBest Practice & Research Clinical Endocrinology & Metabolism, 2012
- A new endoscopic surgical classification and invasion criteria for pituitary adenomas involving the cavernous sinusTurkish Neurosurgery, 2011
- Assessment of the internal craniocervical ligaments with a new magnetic resonance imaging sequence: three-dimensional turbo spin echo with variable flip-angle distribution (SPACE)Magnetic Resonance Imaging, 2009
- Usefulness of Contrast-Enhanced T1-Weighted Sampling Perfection with Application-Optimized Contrasts by Using Different Flip Angle Evolutions in Detection of Small Brain Metastasis at 3T MR Imaging: Comparison with Magnetization-Prepared Rapid Acquisition of Gradient Echo ImagingAmerican Journal of Neuroradiology, 2009
- Evaluation of magnetic resonance imaging criteria for cavernous sinus invasion in patients with pituitary adenomas: logistic regression analysis and correlation with surgical findingsSurgical Neurology, 2006
- Application of three-tesla magnetic resonance imaging for diagnosis and surgery of sellar lesionsJournal of Neurosurgery, 2004
- Pituitary Adenomas with Invasion of the Cavernous Sinus SpaceNeurosurgery, 1993