Surgical outcomes of the coracoid process fracture associated with the acromioclavicular joint injury in Korea: a case series
Open Access
- 25 January 2026
- journal article
- Published by The Korean Orthopaedic Trauma Association in Journal of Musculoskeletal Trauma
- Vol. 39 (1) , 54-61
Abstract
Background: Excluding technical reports and isolated case reports, there are no published studies evaluating coracoid process fixation with or without an acromioclavicular joint (ACJ) stabilization procedure for coracoid process fractures associated with ACJ injury. The purpose of this study was to assess the surgical outcomes of coracoid process fractures associated with ACJ injuries and to determine the usefulness of coracoid process fixation with or without an ACJ stabilization procedure.Methods: From February 2006 to December 2015, patients with coracoid process fractures associated with ACJ injuries were enrolled. Radiological and clinical outcomes were analyzed in 12 patients who underwent coracoid process fixation with or without an ACJ stabilization procedure. A 3.5-mm cannulated screw with a washer or a 3.0-mm headless compression screw was used for coracoid process fixation, and either a clavicle hook plate or Kirschner (K)-wires were used for ACJ injuries when additional fixation was necessary.Results: Bone union was achieved in 11 patients (91.7%), while one case was determined to be a nonunion at 6 months. Radiological union occurred at an average of 3 months (range, 1.5–4 months) in all patients except the nonunion case. At the final follow-up, the average clinical scores were a visual analogue scale (VAS) pain score of 1.5 (range, 0–4) and a UCLA score of 30.9 (range, 28–35). Clinical outcomes were satisfactory in all patients, including the patient with nonunion.Conclusion: The clinical and radiological outcomes of treating coracoid process fractures associated with ACJ injuries using coracoid process fixation with or without ACJ stabilization were favorable. A cannulated screw with a washer and clavicle hook plate fixation may provide sufficient stability for both the coracoid process fracture and the ACJ injury when feasible.Level of evidence: IV.Keywords
This publication has 10 references indexed in Scilit:
- Treatment of coracoid process fractures combined with acromioclavicular joint dislocation using clavicular hook plateJournal of Shoulder and Elbow Surgery, 2023
- Concomitant coracoid base fracture and acromioclavicular joint disruption: A series of patients treated with a clavicle hook plate and review of the literatureJournal of Orthopaedic Surgery, 2022
- Nonunion of the coracoid process: a systematic reviewArchives of orthopaedic and trauma surgery, 2020
- Clinical and Radiologic Outcomes of Acute Acromioclavicular Joint Dislocation: Comparison of Kirschner's Wire Transfixation and Locking Hook Plate FixationClinics in Shoulder and Elbow, 2014
- Orthogonal Biplanar Fluoroscopy-guided Percutaneous Fixation of a Coracoid Base Fracture Associated With Acromioclavicular Joint DislocationTechniques in Hand & Upper Extremity Surgery, 2012
- Displaced Fracture of the Coracoid Process Associated With Acromioclavicular Dislocation: A Two-Bird–One-Stone SolutionJournal of Trauma: Injury, Infection & Critical Care, 2009
- Operative treatment of scapular fractures: A systematic reviewInjury, 2008
- Treatment of Scapula Fractures: Systematic Review of 520 Fractures in 22 Case SeriesJournal of Orthopaedic Trauma, 2006
- Double Disruptions of the Superior Shoulder Suspensory ComplexJournal of Orthopaedic Trauma, 1993
- A biomechanical comparison of scaphoid screwsThe Journal of Hand Surgery, 1987