Abstract
Turn fault detection technique is of key importance for system safety, which can protect the machine and enable the appropriate mitigation strategies. In this article, an advanced turn fault detection method is investigated for an interior permanent magnet machine (IPM) using the ripple current induced by the inherent pulse width modulation (PWM) voltage harmonics. The resultant current harmonics under high-frequency voltage harmonics are analyzed for both healthy and turn fault conditions. The feasibility of the detection method is validated by both simulation studies and prototype tests. It is confirmed that the PWM ripple current-based diagnosis technique can be employed to detect the turn fault in IPM without introducing undesirable noises and vibrations, and it is capable to detect early turn fault.
Funding Information
  • National Natural Science Foundation of China (51907028, 51937006, 51991382)
  • Jiangsu Planned Projects for Postdoctoral Research Funds (2020Z018)
  • Jiangsu Provincial Key Laboratory of Smart Grid Technology and Equipment
  • “Hong Kong Scholar” Program (XJ2019030)
  • “SEU Zhishan Young Scholars” Program of Southeast University
  • State Key Laboratory of Smart Grid Protection and Control

This publication has 22 references indexed in Scilit: