Catch-and-display immunoassay for digital biomarker detection
- 27 May 2026
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Nanoscale Horizons
- Vol. 11 (7) , 1965-1977
Abstract
Digital immunoassays provide exceptional analytical sensitivity for detecting low-abundance biomarkers, but their broad adoption is limited by practical barriers. Commercial platforms are prohibitively expensive for routine use in individual laboratories, and laboratory-scale concepts typically describe specialized biosensors and sophisticated workflows. Here, we introduce a nanomembrane-based Catch-and-Display Immunoassay (CAD-IA), a cost-effective and laboratory-friendly digital immunoassay for common research settings. In CAD-IA, fluorescent nanoparticles are “captured” by the nanoscale pores of ultrathin silicon nitride membranes through a pipette powered filtration. The captured nanoparticles serve as optically isolated ‘hotspots’ for fluorescent immunocomplex formation when target antigen is present. Co-localization of the fluorescent particles and fluorescent immunocomplexes are then “displayed” and quantified by standard confocal microscopy to generate digital signals. CAD-IA is implemented using the µSiM-DX (microfluidic device featuring an ultrathin silicon membrane for diagnostics) platform, which is manually assembled from mass produced, cost-effective components. Using the traumatic brain injury (TBI) biomarker S100B as a model, we demonstrate that CAD-IA provides consistent digital outputs and linear quantification over a dynamic range of at least two orders of magnitude when digital and analog analyses are combined on the same image sets. We further demonstrate that the assay maintains linearity in serum matrices and achieves suitable sensitivity (LoD = 0.02 µg mL−1) for clinically relevant diagnostic with the addition of tyramide signal amplification (TSA). While further optimization of CAD-IA is possible, these results constitute a proof-of-concept demonstration of a novel digital immunoassay deployable in most research laboratories.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (RO1EB03158)
This publication has 69 references indexed in Scilit:
- Shear Conditioning Promotes Microvascular Endothelial Barrier Resilience in a Human BBB‐on‐a‐Chip Model of Systemic Inflammation Leading to AstrogliosisAdvanced Science, 2025
- Accuracy of GFAP and UCH-L1 in predicting brain abnormalities on CT scans after mild traumatic brain injury: a systematic review and meta-analysisEuropean Journal of Trauma and Emergency Surgery, 2025
- Rapid Assessment of Biomarkers on Single Extracellular Vesicles Using “Catch and Display” on Ultrathin Nanoporous Silicon Nitride MembranesSmall, 2024
- The Modular µSiM: A Mass Produced, Rapidly Assembled, and Reconfigurable Platform for the Study of Barrier Tissue Models In VitroAdvanced Healthcare Materials, 2022
- Review: immunoassays in DNA damage and instability detectionCellular and Molecular Life Sciences, 2019
- A review of the clinical utility of serum S100B protein levels in the assessment of traumatic brain injuryActa Neurochirurgica, 2016
- Tyramide Signal Amplification for Immunofluorescent Enhancement2015
- A Literature Review of the Feasibility of Glial Fibrillary Acidic Protein as a Biomarker for Stroke and Traumatic Brain InjuryMolecular Diagnosis & Therapy, 2012
- Tyramide signal amplification for analysis of kinase activity by intracellular flow cytometryCytometry Part A, 2010
- Catalyzed reporter deposition, a novel method of signal amplification application to immunoassaysJournal of Immunological Methods, 1989