Background: To evaluated the feasibility and safety of new aortic valved stents in transcatheter aortic valve implantation (TAVI) using retrograde approach by in vitro testing and animal implantation. Materials and Methods: The fluid passing test, expanding and releasing tests, static and releasing tests in tube were performed for new valved stents. Transvalvular pressure gradient, effective orifice area, pre-implantation and post-implantation regurgitant volume for the new stents were detected. Then, the new stents were implanted in six pigs using retrograde approach. These pigs were euthanized 12 h after the implantation for anatomic evaluation. Results: In vitro tests showed that the closure of the new stents leaflets were effective, and stents could be released through catheter, then expanded completely and fixed fast in the tube. The coronary artery flow rates did not changed significantly after implantation (P > 0.05), while aortic regurgitant volumes were obviously reduced (P < 0.05). No significant difference in the transvalvular pressure gradient and effective orifice area of the new stents implanted within or above the valve leaflets was found (P > 0.05). In vivo experiments indicated that TAVI was successfully performed in six pigs using retrograde approach. However, one pig was died 10 h after the implantation since the stent was not expanded completely. The leaflets in stents were opening well and no valvular regurgitation was observed in the other five pigs. And thrombosis was not found. Discussion and Conclusion: The new type of aortic valved stent designed in this study was characterized with good stability and could avoid the impact caused by valve leaflets on the coronary artery.Keywords
This publication has 33 references indexed in Scilit:
- Advances in antiplatelet technologies to improve cardiovascular disease morbidity and mortality: a review of ticagrelorClinical Pharmacology: Advances and Applications, 2013
- Transcatheter transapical mitral valve-in-valve implantations for a failed bioprosthesis: A case seriesThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Good outcome and valve function despite medtronic‐corevalve underexpansionCatheterization and Cardiovascular Interventions, 2010
- Coronary flow obstruction in percutaneous aortic valve replacement. An in vitro studyEuropean Journal of Cardio-Thoracic Surgery, 2007
- Clinical Profile and Natural History of 453 Nonsurgically Managed Patients With Severe Aortic StenosisThe Annals of Thoracic Surgery, 2006
- Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve DiseaseCirculation, 2006
- Percutaneous Aortic Valve Implantation Retrograde From the Femoral ArteryCirculation, 2006
- Percutaneous aortic valve replacement: resection before implantation?European Journal of Cardio-Thoracic Surgery, 2005
- Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic StenosisCirculation, 2002
- Tissue engineering heart valves: Valve leaflet replacement study in a lamb modelThe Annals of Thoracic Surgery, 1995