Abstract
The accurate localization of the radiated passive intermodulation (R-PIM) source generated inside the phased array has become an increasingly critical issue to guarantee the high communication quality of wireless communication systems. Due to the characteristic of the spatial-temporal focusing, time reversal (TR) imaging is a promising solution for locating the R-PIM source in complex structures and complicated environments, which is yet always analyzed through numerical simulations. This letter develops the truncated TR operator multiple signals classification (TTRO-MUSIC) imaging method for accurate experimental localization of the R-PIM source. In the experimental platform of locating the R-PIM sources using TTRO-MUSIC, the R-PIM source is imitated by the sleeve antenna and placed inside the semi-closed metal cavity. The experimental results show that the positioning error of 0.12 wavelengths can be obtained by TTRO-MUSIC, and additional perturbations only raise the positioning error to 0.14 wavelengths. Compared to the 0.07 wavelengths obtained by the full-wave simulation, the ability to accurately locate the R-PIM source using TTRO-MUSIC has been validated because the intrinsic perturbations in the experimental data are considered.
Funding Information
  • Fundamental Research Funds for the Central Universities (ZYGX2021YGCX008)
  • 2023 Radiation Oncology Key Laboratory of Sichuan Province

This publication has 12 references indexed in Scilit: