An evaluation of gating window size, delivery method, and composite field dosimetry of respiratory-gated IMRT
- 22 October 2002
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 29 (11) , 2517-2525
Abstract
A respiratory gating system has been developed based on a commercial patient positioning system. The purpose of this study is to investigate the ability of the gating system to reproduce normal, nongated IMRT operation and to quantify the errors produced by delivering a nongated IMRT treatment onto a moving target. A moving phantom capable of simultaneous two-dimensional motion was built, and an analytical liver motion function was used to drive the phantom. Studies were performed to assess the effect of gating window size and choice of delivery method (segmented and dynamic multileaf collimation). Additionally, two multiple field IMRT cases were delivered to quantify the error in gated and nongated IMRT with motion. Dosimetric error between nonmoving and moving deliveries is related to gating window size. By reducing the window size, the error can be reduced. Delivery error can be reduced for both dynamic and segmented delivery with gating. For the implementation of dynamic IMRT delivery in this study, dynamic delivery was found to generate larger delivery errors than segmented delivery in most cases studied. For multiple field IMRT delivery, the largest errors were generated in regions where high field modulation was present parallel to the axis of motion. Gating was found to reduce these large errors to clinically acceptable levels.Keywords
This publication has 16 references indexed in Scilit:
- Determining parameters for respiration‐gated radiotherapyMedical Physics, 2001
- Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary functionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Determination of ventilatory liver movement via radiographic evaluation of diaphragm positionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- HIGH DOSE RADIATION DELIVERED BY INTENSITY MODULATED CONFORMAL RADIOTHERAPY IMPROVES THE OUTCOME OF LOCALIZED PROSTATE CANCERJournal of Urology, 2001
- Organ motion and its managementInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2001
- Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose deliveryMedical Physics, 2000
- A comparison of beam characteristics for gated and nongated clinical x-ray beamsMedical Physics, 1999
- A method for incorporating organ motion due to breathing into 3D dose calculationsMedical Physics, 1999
- A software tool for the quantitative evaluation of 3D dose calculation algorithmsMedical Physics, 1998
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998