Abstract
In recent years, robots have become commonplace in surgical procedures due to their high accuracy and repeatability. The Acrobot Sculptor is an example of such a robot that can assist with unicompartmental knee replacement. In this study, we aim to evaluate the accuracy of the robot (software and hardware) in a clinical setting. We looked at (1) segmentation by comparing the segmented data from Sculptor software to other commercial software, (2) registration by checking the inter- and intraobserver repeatability of selecting set points, and finally (3) sculpting (cases) by evaluating the achieved implant position and orientation relative to that planned. The results from segmentation and registration were found to be accurate. The highest error was observed in flexion extension orientation of femoral implant (°). Mean compound rotational and translational errors for both components were mm and° for tibia and mm and° for the femur. The results from all processes used in Acrobot were small. Validation of robot in clinical settings is highly vital to ensure a good outcome for patients. It is therefore recommended to follow the protocol used here on other available similar products.
Keywords
Funding Information
- Wellcome Trust
- EPSRC
This publication has 23 references indexed in Scilit:
- Robotic Assistance Enables Inexperienced Surgeons to Perform Unicompartmental Knee Arthroplasties on Dry Bone Models with Accuracy Superior to Conventional MethodsAdvances in Orthopedics, 2013
- Accuracy of Dynamic Tactile-Guided Unicompartmental Knee ArthroplastyThe Journal of Arthroplasty, 2012
- Imagelessversusimage-based registration in navigated arthroscopy of the hipThe Journal of Bone and Joint Surgery. British volume, 2012
- Active shape modeling of the hip in the prediction of incident hip fractureJournal of Bone and Mineral Research, 2010
- Validation of statistical shape model based reconstruction of the proximal femur—A morphology studyMedical Engineering & Physics, 2010
- Unicondylar knee arthroplasty in the UK National Health Service: An analysis of candidacy, outcome and cost efficacyThe Knee, 2009
- CT-based planning of a single-radius femoral component in total knee arthroplasty using the ROBODOC systemComputer Aided Surgery, 2008
- Robots in Orthopaedic SurgeryClinical Orthopaedics and Related Research, 2007
- Early Failure of Unicompartmental Knee ArthroplastyThe Journal of Arthroplasty, 2007
- Hands-on robotic unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006