A Comparative Study of Strain and Shear-Wave Elastography in an Elasticity Phantom
- 1 March 2015
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 204 (3) , W236-W242
Abstract
OBJECTIVE. The purpose of this study was to assess the diagnostic accuracy of strain and shear-wave elastography for determining targets of varying stiffness in a phantom. The effect of target diameter on elastographic assessments and the effect of depth on shear-wave velocity were also investigated. MATERIALS AND METHODS. We examined 20 targets of varying diameters (2.5-16.7 mm) and stiffnesses (8, 14, 45, and 80 kPa) with a 4-9-MHz linear-array transducer. Targets were evaluated 10 times with three different methods-shear-wave elastography, strain ratio, and strain histogram analysis-yielding 600 evaluations. AUCs were calculated for data divided between different stiffnesses. A 1.5-6-MHz curved-array transducer was used to assess the effect of depth (3.5 vs 6 cm) on shear-wave elastography in 80 scans. Mixed model analysis was performed to assess the effect of target diameter and depth. RESULTS. Strain ratio and strain histogram AUCs were higher than the shear-wave velocity AUC (p < 0.001) in data divided as 80 versus 45, 14, and 8 kPa. In data divided as 80 and 45 versus 14 and 8 kPa, the methods were equal (p = 0.959 and p = 1.000, respectively). Strain ratios were superior (p = 0.030), whereas strain histograms were not significantly better (p = 0.083) than shear-wave elastography in data divided as 80, 45, and 14 versus 8 kPa. Target diameter had an effect on all three methods (p = 0.001). Depth had an effect on shear-wave velocity (p = 0.001). CONCLUSION. The ability to discern different target stiffnesses varies between shear-wave and strain elastography. Target diameter affected all methods. Shear-wave elastography is affected by target depth.Keywords
This publication has 36 references indexed in Scilit:
- Comparison of Shear-Wave and Strain Ultrasound Elastography in the Differentiation of Benign and Malignant Breast LesionsAmerican Journal of Roentgenology, 2013
- EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and TechnologyUltraschall in der Medizin - European Journal of Ultrasound, 2013
- Accuracy of quantitative ultrasound elastography for differentiation of malignant and benign breast abnormalities: a meta-analysisBreast Cancer Research and Treatment, 2012
- Quantitative Measurement for Thyroid Cancer Characterization Based on ElastographyJournal of Ultrasound in Medicine, 2011
- Significant Differentiation of Focal Breast Lesions: Raw Data-Based Calculation of Strain RatioUltraschall in der Medizin - European Journal of Ultrasound, 2011
- Endorectal elastography in the evaluation of rectal tumoursColorectal Disease, 2010
- Significant Differentiation of Focal Breast LesionsAcademic Radiology, 2010
- Thyroid Gland Tumor Diagnosis at US ElastographyRadiology, 2005
- Elastography of breast lesions: initial clinical results.Radiology, 1997
- Elastography: A Quantitative Method for Imaging the Elasticity of Biological TissuesUltrasonic Imaging, 1991