The Pentax airway scope versus the Macintosh laryngoscope: Comparison of hemodynamic responses and concentrations of plasma norepinephrine to tracheal intubation
Author:
Open Access
- 1 January 2013
- journal article
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 64 (4) , 315-320
Abstract
The Pentax Airway Scope (AWS) is a video laryngoscope designed to facilitate tracheal intubation with a high-resolution image. The Pentax AWS has been reported to cause less hemodynamic stress than the Macintosh laryngoscope. The aims of this study are to investigate the differences in hemodynamic responses and norepinephrine concentrations to tracheal intubation between procedures using he Pentax AWS and the Macintosh laryngoscope. Forty patients (American Society of Anesthesiologists class I-II, age range: 18-60 years) were randomly assigned to be intubated with either the Pentax AWS or the Macintosh laryngoscope while under general anesthesia. Routine monitoring, including invasive arterial blood pressure and bispectral index, were applied. Thiopental (4 mg/kg), fentanyl (1 µg/kg), midazolam (0.05 mg/kg), and rocuronium (0.6 mg/kg) were administered for anesthetic induction. Systolic, diastolic, and mean blood pressures and heart rates were recorded pre-intubation, immediately post-intubation (T0), and over the following 10 minutes at one minute intervals (T1, T2, T3, T4, T5…T10). Patient blood was sampled for norepinephrine concentrations pre-intubation (baseline) and post-intubation (T1). Evidence of sore throat was evaluated 30 min and 24 hr after extubation. Data were transformed to % basal and expressed as mean ± SD. The systolic, diastolic, and mean blood pressure, and heart rate at T0 and T4 were significantly different between the two groups. There was no significant difference in plasma norepinephrine between the two groups. The difference in incidence of sore throat was not significant between the two groups. Pentax-AWS for tracheal intubation has greater hemodynamic stability than the Macintosh blade laryngoscope.Keywords
This publication has 23 references indexed in Scilit:
- Tracheal Intubation With the PENTAX-AWS (Airway Scope) Reduces Changes of Hemodynamic Responses and Bispectral Index Scores Compared With the Macintosh LaryngoscopeJournal of Neurosurgical Anesthesiology, 2009
- Cervical Spine MotionAnesthesiology, 2009
- Tracheal intubation in patients with cervical spine immobilization: a comparison of the Airwayscope®, LMA CTrach®, and the Macintosh laryngoscopesBritish Journal of Anaesthesia, 2009
- Comparison of Macintosh, Truview EVO2®, Glidescope®, and Airwayscope® laryngoscope use in patients with cervical spine immobilizationBritish Journal of Anaesthesia, 2008
- Pentax-AWS, a new videolaryngoscope, is more effective than the Macintosh laryngoscope for tracheal intubation in patients with restricted neck movements: a randomized comparative studyBritish Journal of Anaesthesia, 2008
- Cardiovascular responses to tracheal intubation with the Airway Scope (Pentax-AWS)Journal of Anesthesia, 2008
- A comparison of the stress response to laryngoscopyAnaesthesia, 1995
- Circulatory responses to laryngeal mask airway insertion or tracheal intubation in normotensive and hypertensive patientsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1995
- Stress response to tracheal intubation: direct laryngoscopy compared with blind oral intubationAnaesthesia, 1995
- Cardiovascular response to intubationAnaesthesia, 1983