Stabilized Hemocompatible Coating of Nitinol Devices Based on Photo-Cross-Linked Alginate/Heparin Multilayer
Authors:
- 31 July 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 23 (18) , 9378-9385
Abstract
A novel stabilized hemocompatible multicomponent coating was engineered by consecutive alternating adsorption of two polysaccharides, alginate (Alg) and heparin (Hep), onto a Nitinol surface via electrostatic interaction in combination with photoreaction in situ. For this purpose, a photosensitive cross-linker, p-diazonium diphenyl amine polymer (PA), was used as an interlayer between alginate and heparin. The optical intensity of UV/vis spectra increased linearly with the number of layers, indicating the buildup of a multilayer structure and uniform coating. Photo-cross-linking resulted in higher stability without compromising its catalytic capacity to promote antithrombin III (ATIII)-mediated thrombin inactivation. Chromogenic assays for heparin activity proved definitively that anticoagulation activity really comes from surface-bound heparin in multilayer film, not from solution-phase free heparin that has leaked from multilayer film. The activated partial thromboplastin time (aPTT) assay showed that both (PA/Hep)8- and (PA/Alg/PA/Hep)4-coated Nitinol were less thrombogenic than the uncoated one. Yet, the latter was found to be more stable under a continuous shaken wash. In addition, (PA/Alg/PA/Hep)4 film exhibited lower suface roughness and higher hydrophilicity than (PA/Hep)8. As a result, hemolysis of (PA/Alg/PA/Hep)4 (0.34 ± 0.064%) was lower than (PA/Hep)8 (0.52 ± 0.241%). The naked Nitinol and (PA/Hep)8-coated Nitinol showed relatively strong platelet adhesion. On the contrary, no sign of any cellular matter was seen on the (PA/Alg/PA/Hep)4 surface. It is believed that the phenomenon of interlayer diffusion resulted in blended structures, hence, the enhanced wettability and antifouling properties after the incorporation of alginate layers. It is likely that the cooperative effect of alginate and heparin led to the excellent blood compatibility of the (PA/Alg/PA/Hep)4 coating. To simplify, there is greater advantage in utilizing cross-linked alginate/heparin surfaces rather than merely the heparin surface for improving blood- and tissue-compatible devices.Keywords
This publication has 49 references indexed in Scilit:
- Nitinol – Its Use in Vascular Surgery and Other ApplicationsEuropean Journal of Vascular and Endovascular Surgery, 2000
- Immunologic mechanisms in hypersensitivity reactions to metal ions: an overviewAllergy, 2000
- Dissolution of nickel and tissue response observed by X-ray scanning analytical microscopyBiomaterials, 1999
- Biocompatibility of polymer-coated oversized metallic stents implanted in normal porcine coronary arteriesAtherosclerosis, 1995
- Nickel-Titanium Memory Metal: A "Smart" Material Exhibiting a Solid-State Phase Change and SuperelasticityJournal of Chemical Education, 1994
- Intravascular stents: tissue-stent interactions and design considerations.American Journal of Roentgenology, 1993
- A new expandable intracoronary tantalum (Strecker) stent: Early experimental results and follow-up to twelve monthsAmerican Heart Journal, 1993
- Placement of Balloon-expandable Intraluminal Stents in Iliac Arteries: First 171 ProceduresRadiology, 1990
- Self-expanding endovascular graft: an experimental study in dogsAmerican Journal of Roentgenology, 1988
- Investigation of three‐surface properties of several metals and their relation to blood compatibilityJournal of Biomedical Materials Research, 1972