Validation of the Flush Method as an Alternative to Basal or Reflex Tear Collection
- 15 December 2010
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 36 (3) , 198-207
Abstract
Purpose: To validate the more easily applicable “flush” tear collection technique as a viable alternative to basal and reflex tear collection. Materials and Methods: Total protein content (TPC) and immunoglobulin A (IgA) concentrations were determined in the basal, reflex, and flush tears of 16 healthy non-contact lens wearers. The overall protein profile was established using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and mass spectrometry (MS). Results: Collection-rates were 4.6 ± 6.7 μl/min, 13.9 ± 11.1 μl/min, and 25.7 ± 12.4 μl/min for the basal, reflex, and flush tears, respectively. TPC was 7.14 ± 2.22 mg/mL, 6.01 ± 2.11 mg/mL, and 3.79 ± 1.51mg/ mL for basal, reflex, and flush tears, respectively, with flush tears being significantly less concentrated than basal (p = 0.001) and reflex (p = 0.008). IgA concentration was 1.04 ± 0.29 mg/ mL, 0.64 ± 0.26 mg/mL, and 0.65 ± 0.23 mg/mL for basal, reflex, and flush tears, respectively, with basal tears being significantly more concentrated (p < 0.001). As a percentage of TPC, IgA represented 19.8 ± 14.9%, 11.4 ± 3.9%, and 19.8 ± 8.7% for basal, reflex, and flush, respectively. The flush was not significantly different to basal (p = 1.00) but significantly greater than reflex (p = 0.02). SDS-PAGE showed the same tear profiles for basal and flush tears. MS identified the most abundant proteins in all tear types. Conclusions: The flush method allows much faster collection than basal secretion sampling but returns essentially the same spectrum of proteins in similar proportions. This behavior is confirmation that the flush technique has utility as a more convenient alternative to basal tear sampling in studies involving composition analysis.Keywords
This publication has 29 references indexed in Scilit:
- Antibody Protein Array Analysis of the Tear Film CytokinesOptometry and Vision Science, 2008
- Upregulation of Matrix Metalloproteinase in Tear Fluid of Patients with Recurrent Corneal ErosionJapanese Journal of Ophthalmology, 2007
- Tear Glucose Dynamics in Diabetes MellitusCurrent Eye Research, 2006
- Membrane Array Characterization of 80 Chemokines, Cytokines, and Growth Factors in Open- and Closed-Eye Tears: Angiogenin and Other Defense System ConstituentsInvestigative Ophthalmology & Visual Science, 2005
- Differences in Clinical Parameters and Tear Film of Tolerant and Intolerant Contact Lens WearersInvestigative Ophthalmology & Visual Science, 2003
- Levels of Collagen Degradation Products (Telopeptides) in the Tear Film of Patients with KeratoconusCornea, 2000
- Contact Lens Wear Alters the Production of Certain Inflammatory Mediators in TearsExperimental Eye Research, 2000
- Tear changes in contact lens wearers following overnight eye closureCurrent Eye Research, 1998
- Effect of hydrogel lens wear on the major tear proteins during extended wearAustralian and New Zealand Journal of Ophthalmology, 1997
- Effects of the Schirmer test on the fibrinolytic system in the tear fluidExperimental Eye Research, 1990