Automatic Sampling and Analysis of Organics and Biomolecules by Capillary Action-Supported Contactless Atmospheric Pressure Ionization Mass Spectrometry
Open Access
- 6 June 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (6) , e66292
Abstract
Contactless atmospheric pressure ionization (C-API) method has been recently developed for mass spectrometric analysis. A tapered capillary is used as both the sampling tube and spray emitter in C-API. No electric contact is required on the capillary tip during C-API mass spectrometric analysis. The simple design of the ionization method enables the automation of the C-API sampling system. In this study, we propose an automatic C-API sampling system consisting of a capillary (∼1 cm), an aluminium sample holder, and a movable XY stage for the mass spectrometric analysis of organics and biomolecules. The aluminium sample holder is controlled by the movable XY stage. The outlet of the C-API capillary is placed in front of the orifice of a mass spectrometer, whereas the sample well on the sample holder is moved underneath the capillary inlet. The sample droplet on the well can be readily infused into the C-API capillary through capillary action. When the sample solution reaches the capillary outlet, the sample spray is readily formed in the proximity of the mass spectrometer applied with a high electric field. The gas phase ions generated from the spray can be readily monitored by the mass spectrometer. We demonstrate that six samples can be analyzed in sequence within 3.5 min using this automatic C-API MS setup. Furthermore, the well containing the rinsing solvent is alternately arranged between the sample wells. Therefore, the C-API capillary could be readily flushed between runs. No carryover problems are observed during the analyses. The sample volume required for the C-API MS analysis is minimal, with less than 1 nL of the sample solution being sufficient for analysis. The feasibility of using this setup for quantitative analysis is also demonstrated.Keywords
This publication has 27 references indexed in Scilit:
- Syringe Infusion-based Contactless Atmospheric Pressure Ionization Mass Spectrometry for Small and Large BiomoleculesMass Spectrometry Letters, 2012
- Quantitative Real-Time Monitoring of Chemical Reactions by Autosampling Flow Injection Analysis Coupled with Atmospheric Pressure Chemical Ionization Mass SpectrometryAnalytical Chemistry, 2012
- High-Throughput Trace Analysis of Explosives in Water by Laser Diode Thermal Desorption/Atmospheric Pressure Chemical Ionization-Tandem Mass SpectrometryAnalytical Chemistry, 2012
- Online monitoring of chemical reactions by contactless atmospheric pressure ionization mass spectrometryJournal of Mass Spectrometry, 2012
- An instrumentation perspective on reaction monitoring by ambient mass spectrometryTrAC Trends in Analytical Chemistry, 2012
- Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 2011
- Laserspray Ionization, a New Atmospheric Pressure MALDI Method for Producing Highly Charged Gas-phase Ions of Peptides and Proteins Directly from Solid SolutionsMolecular & Cellular Proteomics, 2010
- Scanning Mass Spectrometry Probe: A Scanning Probe Electrospray Ion Source for Imaging Mass Spectrometry of Submerged Interfaces and Transient Events in SolutionAnalytical Chemistry, 2009
- Negative ion ‘chip‐based’ nanospray tandem mass spectrometry for the analysis of flavonoids in glandular trichomes of Lychnophora ericoides Mart. (Asteraceae)Rapid Communications in Mass Spectrometry, 2008
- Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient ConditionsAnalytical Chemistry, 2005